BEWARE:
You must adhere to the Safety Precauons of EN 60728-11
•
Before you start working on the installaon, turn off Mains Power to the circuit.
•
Only let an authorized Elecctrician do the Mains power plug installaon if needed.
•
Never do Installaon or Repair during Thundr Storms.
•
Always connect the network by use of the Grounding Terminal of the device (with a
copper wire (diameter min. 4 mm
2
) to the Building Grounding Terminal!
Before you start working on the installaon, turn off Mains Power to the circuit!
Observe the safety precauons!
Mount the Amplifier...
•
Horizontal, free on the wall and so that the convecon cooling of the unit
is not compromized.
•
On non-flammable material (Concrete or Brick Wall)
•
In a dusree environment, protected against moisture and fluid.
(Drop– and spray water)
•
Not in a spot with direct Sun radiaon (e.g.. On the Roof)
•
Not directly along with Heat Sources (e.g. Heang Room)
•
In compliance with the highest allowed working Temperature
(measured at the Airflow under the Amplifier)
Wallmounng:
Fasten the Amplifier according to its measurements (See Fig. 1.) on the wall.
(Screws-ø max. 4.8 mm, Distance between holes 158 mm)
Create a Grounding potenal using the screw A and a sufficient fied and stable
cable (diameter min. 4 mm
2
)
Connect the RF-Input B and the RF-Output C. Make sure you get perfect
connecon between Coax cable and Connector.
Turn on the Mains Power to the circuit again.
Fig. 1 Mounng
Installaon
English