Configuring CA modules 

8

 The 

CA Module setup

 window is displayed, initially containing default 

values. 

3.  Specify the speed of the CI card in the 

Card speed

 drop-down list. 

4.  Specify if a 

constant bitrate

 is to be used. 

5.  Select the service(s) that are to be descrambled (indicated by ‘$’) in 

the Service list area. 

6.  Select the 

ER

 checkbox to enable automatic error recovery for the 

service.

Signal transmission status through the CA module is constantly 

monitored when the 

ER

 checkbox is enabled, with the CA module being 

automatically reset in the event of data transmission failure. Note that 

signal transmission will be interrupted for all the services associated with 

the CA module when the error recovery monitoring prompts the resetting 

of the CA Module. 
The

ER

 checkbox should not be enabled for services where signals are 

not transmitted on a 24-hour basis. 

 

7.  Press the 

Setup

 button for the selected service. 

Tabs

CA module

Common interface

 button 

Submit button 

Reset CAM button 

Apply button 

Service list 

area 

Status area 

Configuring CA modules 

9

 The 

Filter options

 window is set by default to descramble all audio 

PIDs associated with the service. 

 

8. Enable  the 

Descramble non audio/video PIDs

 checkbox to 

descramble all PIDs associated with the service, that are neither 

audio, or video related. 

 

9. Disable the 

Descramble all audio PIDs

 checkbox to limit the 

number of audio PIDs to be descrambled to specific languages. 

10. Select an audio PID to be descrambled. 

11. Select (if required) additional audio PIDs. 

12. Press  the 

OK

 button. 

Note that an additional language drop-down list is displayed each time a 

Содержание 692850

Страница 1: ...Model Item no TDH 800 PAL output module 692850 692851 Version 891575A 08 2013 EN triax com Configuration guide TDH 800 PAL output module...

Страница 2: ...c IP address 3 Physical connection to headend 3 Service tool 4 Overview 5 Icons 5 Tabs 6 Misc Buttons 6 Configuring CA modules 7 Pre requisites 7 Configuration 7 Resetting 10 Modifying 11 Deleting 12...

Страница 3: ...elded cable or better between the computer s network port and the configuration port on the headend Introduction 3 Introduction This document describes the configuration of the PAL Output module for t...

Страница 4: ...web address field 3 Press Enter 4 Enter the password 5 Press the Log in button Note Password triax1234 when the service tool is opened for the first time The Keep me logged in checkbox overrides the...

Страница 5: ...ool and headend are communicating correctly Red The service tool and headend are NOT communicating correctly Indicates whether the headend unit is functioning correctly Green The headend unit is funct...

Страница 6: ...ormation Network Tab for defining customer specific settings that are network related e g Network name ID and for defining HD SD channel numbering Channel List Tab for viewing the channels being trans...

Страница 7: ...ule the output module is inserted in the headen and the TDH Service Tool is connected to the headend See the TDH 800 Headend User Guide for information on inserting the output module into the TDH 800...

Страница 8: ...through the CA module is constantly monitored when the ER checkbox is enabled with the CA module being automatically reset in the event of data transmission failure Note that signal transmission will...

Страница 9: ...ramble all PIDs associated with the service that are neither audio or video related 9 Disable the Descramble all audio PIDs checkbox to limit the number of audio PIDs to be descrambled to specific lan...

Страница 10: ...button in the CA Module setup window The service s selected in now listed 14 Press the Apply button The following confirmation is displayed Resetting It may be necessary to reset the CA module if it m...

Страница 11: ...transmission through it will be temporally interrupted The ER checkbox can alternatively be enabled to automatically reset CA modules see above Modifying 1 Press the Setup button for the CA module to...

Страница 12: ...Configuring CA modules 12 Deleting 1 Press the Delete button of the CA module to be removed A confirmation popup is displayed 2 Press Yes on the confirmation popup...

Страница 13: ...he output module is in position and the TDH Service Tool is connected to the headend See the TDH 800 Headend User Guide for information on inserting the output module into the TDH 800 headend Configur...

Страница 14: ...or through manual specification Pre defined 1 Select the required Channel plan 2 Select the required Channel Pre defined values are loaded in the Frequency and Channel spacing fields Manual 1 Select F...

Страница 15: ...ke if required additional configuration changes in the following fields drop down lists in the configuration window RF level correction Audio Sub Carrier Attentuation Use Alternative decoder settings...

Страница 16: ...e output module is enabled or disabled SW revision Displays the software version of the input module The software version displayed must be identical with that installed on the TDH 800 main unit and o...

Страница 17: ...t module to be modified 2 Make the desired changes 3 Press the Update button 4 Press the Submit button 5 Press the Apply button in the Configuration window Deleting 1 Press the Delete button of the ou...

Страница 18: ...Configuring PAL output modules 18 5 Restart the headend 6 Restart the service tool The output module will no longer be listed in the input module list...

Страница 19: ...go and TRIAX TRIAX Multimedia are registered trademarks or trademarks of the TRIAX Company or its affiliates All specifications in this guide are subject to change without further notice TRIAX A S Bj...

Отзывы: