2
OPERATING INFORMATION
The Prestige SOLO boiler is controlled by the MCBA
Control module, which is a microprocessor electronic
controller. The MCBA offers various control options
which may be adjusted to the various installation appli-
cations to achieve optimum boiler efficiency and func-
tion.
The MCBA module has the capability to sense the
boiler supply and return water temperature, the flue
gas temperature, the outdoor temperature and the
storage temperature of a SMART / TR Series IDWH or
optional DHW kit (when optional NTC is installed).
The MCBA uses this information to regulate the boil-
er’s on/off operation and modulate the input rate of the
boiler to closely match the required demand of the
heating system.
PROGRAM ACCESS OF THE MCBA
To adjust the factory parameter settings of the Prestige
MCBA the installer must enter into the parameter listing
of the MCBA.
Do not attempt to adjust or revise any parameter
settings except those listed in detail throughout
this manual. A complete listing of factory set-
tings are listed on Page 26 at the end of this
manual if there is doubt or concern that a wrong
setting was revised. Failure to comply could
result in erratic or unreliable operation of the
Prestige boiler.
To enter the parameter listing of the MCBA control, the
installer must enter the activation code as follows:
1. Press and hold the MODE button
2.
Continue holding the MODE and press STEP button
until
STBY
appears and hold both STEP and
MODE buttons for 2 to 3 seconds.
The display should read
CODE
3. Release the STEP and MODE buttons on the con-
trol panel.
4. Press
STEP once.
WARNING
The display should read
C_
XX
(XX should be
a random number from 00 to 99)
5. Press the + or - button to change the display num-
ber
C_
XX
to read
C_05
. Press and release the +
or - to change the display one number at a time.
Press and hold the + or - to rapidly change the dis-
play number.
6. When the display reads
C_05
press STORE to
save the activation code. The display
C_05
should
flash when the code is entered and saved.
After the activation code is entered press the MODE but-
ton until the display shows
PARA
. At this point the
installer can access the parameters required for appli-
cation.
Once in the parameter mode, press the STEP repeated-
ly to reach the appropriate parameter setting. The dis-
play should show the following sequence, as the STEP
button is press repeatedly:
Press STEP once-
1140
Press STEP x2 -
2_01
Press STEP x3 -
3_01
Press STEP x4 -
4186
Press STEP x5 -
P_05
Press STEP x6 -
P_06
Etc......
After Parameter 4 the display will continue to show P fol-
lowed by a two-digit number that increases with each
press of the STEP button.
The actual parameter values displayed on the
unit may vary depending on the application. The
parameter sequence will always occur in the
order shown.
Once a particular parameter sequence is reached,
release the STEP button. Wait a second and the display
will show the current setting for that parameter in the
right two display digits.
NOTICE