background image

Harness Installation Instructions

1.  Turn the power to the unit OFF by disconnect-

ing the main power source.

ELECTRICAL  SHOCK  HAZARD.    The
ON/OFF switch of the boiler does not discon-
nect  electrical  power  to  the  module.
Disconnect    electrical  power  to  the  boiler
using the main service switch.

2. Remove the front jacket panel by loosening the

retaining screws on each side of the display.

3. Dismount the front jacket panel by pulling the

bottom of the front panel out and the entire front
jacket panel down.

4. Pull the Control Display Module tray out from

the  bottom  jacket  panel  and  swing  the  tray
downward.  The guide pins on the front of the
tray should disengage the bottom panel (Fig.2).

5. Install the indirect circulator wiring harness by

feeding the end with 2 ferules and female dis-
connect through the boiler cabinet to the control
module from inside the boiler.  The end of the
wiring  harness  with  the  splicing  connectors

should  be  routed  to  the  line  voltage  terminal
strip area.  See Fig. 3.

6.    Connect  the  green  ground  wire  to  an  available

grounding tab along the top of the control mod-
ule. See Fig. 4.

7.    Connect  the  black  wire  to  X2-5  and  the  white

wire to X2-7.  See Fig. 4.

WARNING

CHALLENGER 

Indirect Circulator

Wiring Harness 

Kit 

2

Fig. 2: Terminal strip access

Fig. 1: Loosening of retained screws

Wiring Harness to

Control Module

Splicing

Connectors

C Clip

Fig.  3:  Indirect  Circulator Wiring  Harness