![Trianco Newton Stoves Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/trianco/newton-stoves/newton-stoves_operation-installation-commissioning-and-servicing-instructions_1159934015.webp)
15
SERVICING
Every year, the stove should be serviced and the chimney
swept. Always use a qualified engineer. The best time is
just after the end of the heating season, when the stove is
not likely to be in use. Allow the stove to cool before the
engineer attends. Procedure:
Remove the front grate, fire bricks, throat plate,
bottom grate and ash pan.
Sweep the chimney thoroughly from an accessible
position (see
fig 5
,
page 12
).
Clear out any large deposits from inside the
combustion chamber and vacuum that which
remains. If necessary, scrape off deposits that have
attached to the walls of the chamber.
Clean the throat plate, bottom grate and front plate
with a wire brush. Use a soft brush for the firebricks.
Replace any damaged items and re-fit in the reverse
order.
Remove the door glass and clean with a damp cloth;
wipe with a dry cloth. Inspect and replace the door
seal if necessary.
Check operation of the door catch, ensuring a tight seal is
made.