6.2 Guide to mechanical installation
The following notes help to carry out the mechanical installation
Site
The servo drive should be mounted into a lockable control cabi-
net. Refer to chapter 5.8.
The site must be free from conductive or corrosive materials.
Cooling
The drives shall be spaced with a gap of 5mm laterally.
The servo drive will shut down if the temperature on the PCB, be-
low the power stage, reaches 70°C.
Mounting
Assemble the servo drives and power supply close together, on
the conductive, grounded mounting plate in the cabinet.
Mount the drive preferably in vertical position as depicted in Fig-
ure 4 (horizontal position is allowed too). There are two mount-
ing holes for this purpose for M4-Screws in a distance of 220mm
at the back side of the drive.
TSD80/TSD130
Gap between drives
10mm
Screws
2 x M4 or M5
Table 15: Distances of drives in cabinet.
HWTSD80-TSD130_4_HardwareManual_EP006
2022-01-27
24/49
Figure 4: Mounting and cooling.
gap