Technical Specifications
Electrical Specifications
All the specifications are given for an ambient temperature ranging from +10°C (50°F) to +40°C (104°F).
TP350
3-phase or
(1-phase)
AC-Line
input
3-phase AC voltage (L-L)
44...230 ± 10%
V AC
1-phase AC voltage
44.. 230 ± 10%
V AC
Nominal frequency
Nominal maximum AC current I
VN
Required external fuse maximum
Power factor correction
50-60
22
20 , e.g. Hager NBN320
no
Hz
A rms
A rms
Transformer Requirements
None, Auto-transformer allowed
DC-Line
input
Input voltage DC
62...368
V DC
Nominal maximum DC current I
VN
Required external fuse maximum
14
16
A
A
Line input
Internal DC-bus fuse (fast)
In-rush limiter
Insulation test voltage
30
250
360
A rms
Ohm
VDC
DC-Bus
output
DC voltage nominal
DC voltage maximum
325
380
V
V
Max current (sum)
continuous
pulse 30s
pulse 2s
14
20
25
A
A
A
Capacitance DC-bus capacitance
2.8 ±20%
mF
Internal
brake
resistor
Brake-point U
Brake
Adiabatic dissipation energy E
A
Continuous power P
C
Resistance
375 ± 2%
5000
50
18
V
J
W
Ohm
Min resistance
15
Ohm
Voltage
Current
24 VDC ±20%
Sum of Fan and Status out current
V
A
Fan 1, Fan 2
Direct connection
24V, 1A
Status out
High-Side switch
24V on/off, 30mA
1 Limited by an internal arrestor circuit.
2 If an external brake resistor is used, it has the same brake-point U
Brake
as if the internal brake resistor is used
3 The Status/Fan supply is galvanically isolated from the internal logic power. It is used only for the fans and the Status out.
4 The fan and status outputs are galvanically connected to the 24V Status/Fan supply.
HWTP50-TP350_E_HardwareManual_EP008
2022-08-08