TRI TOOL INC.
92-1870 Rev. 201007
14
Volume Control:
Pendant rheostat with the integrated Electric Displacement
Control (EDC) Pump.
Pressure
0 psi (0 kPa) to 1800 psi (124.1 bar) forward.
0 psi (0 kPa) to 1800 psi (124.1 bar) reverse.
The system is a closed loop.
A full flow return “loop” 9-micron filter prevents contamination from
circulating through the pump.
The Filter Assembly incorporates a visual Filter Clogging Indicator.
The tank suction line contains a 100-micron suction strainer with 3 psi (.2
bar) relief.
Cooling
A 24 VDC air cooled heat exchanger automatically turns on with the start of
the electric motor. A hot oil shuttle valve flushes oil from the closed circuit low
pressure side and through the heat exchanger. Gloves and PPE are required.
Hydraulic Reservoir
The reservoir has a capacity of 18 gal (68 L).
The reservoir includes a level and a temperature gauge
4.4 HYDRAULIC FLUID COMPATIBILITY
The system requires a petroleum-based hydraulic fluid.
Ethylene glycol/water based fluids may also be used. However, it is
recommended that you contact Tri Tool for important operating information.