8
Issued by:
Arnold Bos / www.tri-sure.com
Issue no.:
MAN-1000029
Version:
2
Date:
11-02-2015
Trade-marks
Tri-Sure® metal closures, Tri-Sure® plastic
closures, Tab-Seal® caps, SambaCap
TM
,
UNI-GRIP® spouts, ULTRA-BOND® spouts,
PLASTIPLUG
TM
plugs, Push-Lock
TM
caps,
PLASTICAP
TM
screw caps, PLASTIROB®
taps, CDS® dispense closures
Disclaimer
: all information on our behalf in relation to our products, whether in nature of date, recommendations or otherwise, is supported by research and believed reliable, but we assume no liability
whatsoever in respect of application, processing or use made of the aforementioned information or products or any consequence thereof. The user undertakes all liability in respect of the application.
Processing or use of the aforementioned information or products, whose quality and other properties he shall verify, or any consequence thereof. No liability whatsoever shall attach to us for any
infringement of the rights owned or controlled by a third party on intellectual, industrial or other property by reason of the application, processing or use of the aforementioned information or products by
the user.
INSTALLATION- AND OPERATING INSTRUCTIONS
English / English
INSTALLATION- AND OPERATING INSTRUCTIONS
for pneumatic Tri-Sure
®
Tab-Seal
®
cap closingtools
type IPT-S
G2
type IPR-S
G3/4
type 60IPU
Uni-Grip
1.
INSTALLATION
-
Install the tool as indicated in drawing TSN939080
-
Adjust the balancer in such a way that the tool is appr. 20 cm above the top of the
drum.
-
Check that the airsupply includes an airvalve, lubricator unit, and pressure regulator.
-
Adjust the airpressure to 5,5 bar.
-
Adjust the lubricator in such a way that regular lubrication takes place.
2.
OPERATION
-
Before use, operate the tool a few times to ensure proper functioning of the tool.
Ensure that the jaws move freely.
-
Regularly lubricate the jaws lightly with oil, and inspect the jaws for contamination
that could prevent proper functioning of the tool.
-
Place the Tri-Sure® Tab-Seal® cap on the Tri-Sure closure. Place one hand on the
upper cylinder and one hand at the control valve and move the tool above the
closure. Excercise light downward pressure till the tool sits on the closure.
-
Operate the airvalve. Release the airvalve as soon as the crimping operation has
been completed.
-
Move the tool away from the closure and visually inspect if the Tri-Sure® Tab-Seal®
cap has been fitted correctly.
3.
SAFETY
-
The use of gloves, eye protection, hearing protection, and
safety footwear is
compulsory.
-
Always operate the tool with both hands.
-
Remove compressed air supply if the tool is not used.
-
Remove compressed air supply during maintenance.
-
Do not touch the jaws when the air supply is connected to the tool.
-
Use this tool only for the purpose for which it is designed.