Trenton Systems TRC4011 Скачать руководство пользователя страница 21

TRC4011 / TVC4403 Installation Guide                                                                                                                                                      

5-1 

 

Trenton Systems, Inc. 

Chapter 5 - Chassis Specifications 

 

E

NVIRONMENTAL

 

 

Temperature 

 

 

Operating 

5

°

C to 35

°

C typical 

 

Storage 

-20

°

C to 70

°

        Cold Excursion Temp    

-40

°

C for up to sixteen hours 

Relative Humidity 

5% to 90%, non-condensing 

 
Specific operating temperature ranges for the TRC4011 / TVC4403 are dependent on the number of option 
cards and other system components installed.  Extended operating temperature CPUs resulting in a 
system’s achievable operating temperature range higher than what is stated here may be available for use 
on the system host inside the TRC4011 / TVC4403.  The reverse can also be true in that a system 
subcomponent could have a lower operating temperature range that could lower the system’s overall 
operating temperature range.  Contact Trenton for more details.  

E

LECTRICAL

 

Line Voltage 

110-240VAC 

Line Frequency 

50-60Hz 

Power Consumption 

450W typical, 800W or 860W max. 

 

P

HYSICAL

 

Approximate Dimensions 
(W x H x D) 

19” x 7.0” x 20.0” 
48.3cm x 17.8cm x 50.8cm 

Net Weight 

24 lbs. (10.9 kg) 

(doesn’t include option cards)

 

 
S

HOCK 

&

 

V

IBRATION

 

Shock - Class 3M4 operational and non-
operational under EN60721-3-3 

10G operating; 100m/s

; Type I  

Vibration - Class 3M4 operational and 
non-operational under EN60721-3-3 

Sinusoidal Vibration: 1G; 3mm; 10 m/s2; 2-9 9-200Hz 

 
A

GENCY 

A

PPROVAL

 

UL 

UL recognized product listed in file #E208896-A3-UL 
dated 2013-02-28 

Environmental 

IEC 60721-3-3:2002 including Class 3K3, 3Z3, 3Z4, 
3M4 and 3S2 
IEC 60721-3-2:1997 including Class IE23 and 2M3  

CE – ECM Directive 2004/108/EC  
         including EMI/EMC 

IEC61000-6-4:2006 & IEC61000-6-2:2005 including: 
CISPR22:1997 + A1:2000 + A2:2002ClassA, 
IEC61000-3-2:2005, IEC61000-3-3:2008, IEC61000-4-
2:2008, IEC61000-4-3:2008 + A1:2010, IEC61000-4-
4:2004 + Al:2010,  IEC61000-4-5:2005, IEC61000-4-
6:2008, IEC61000-4-8:2009 & IEC61000-4-11:2004 

 

Содержание TRC4011

Страница 1: ...TRC4011 4U RACKMOUNT COMPUTER TVC4403 4U Rackmount Video Display Wall Controller No TRC4011 xxx TVC4403 xxx Revision C INSTALLATION GUIDE Publication No 8404011 09142...

Страница 2: ...ilure is caused by accident acts of God or other causes beyond the control of Trenton Trenton reserves the right to make changes or improvements in any product without incurring any obligation to simi...

Страница 3: ...tem variables and application requirements associated with any particular installation Trenton Systems cannot assume responsibility or liability for actual system use based on the examples and diagram...

Страница 4: ...LAYOUT DRAWINGS 2 1 LAYOUT DIMENSION DRAWING 2 1 CHAPTER 3 INSTALLATION INSTRUCTIONS 3 1 ENVIRONMENTAL CONSIDERATIONS 3 1 RACK MOUNTING 3 1 RACKMOUNT INSTRUCTIONS 3 1 SLIDE RAIL INSTALLATION 3 1 CONNE...

Страница 5: ...ng techniques when moving and installing the system When removing or installing boards and sub components keep these components in their static shielded bag and or packaging until you are ready to for...

Страница 6: ...2A and 65A respectively The system s power monitoring circuits will shut the system down if these maximum current limits are drawn from the power supply CHASSIS AIRFLOW When installing the chassis ens...

Страница 7: ...rective 2004 108 EC EMC Directive standards to which conformity is declared BACKPLANE SHB SYSTEM POWER SUPPLY MODELS NOTE The chart below illustrates backplanes SHBs and system power supplies supporte...

Страница 8: ...cessors and six 2GB DDR3 1600 MiniDIMMs installed System Power Supply 800W redundant See the BXT7059 web page for more SHB details See the BPG7087 web page for more backplane details TRC4011 011 OR TV...

Страница 9: ...Fan control kit 3 102CFM system fans Consult with Trenton for available storage drives and optical media drives compatible with the TRC4011 TVC4403 TVC4403 SHB BATTERY CAUTION Risk of explosion if the...

Страница 10: ......

Страница 11: ...nton Systems Inc Chapter2 PhysicalDimensions LayoutDrawings LAYOUT DIMENSION DRAWING Note Ensure that there is at least 4 6 inches 101 152mm front and rear chassis clearance for cable connections and...

Страница 12: ......

Страница 13: ...es of the computer are designed to secure the TRC4011 TVC4403 to the rack cabinet s front mounting rails RACKMOUNT INSTRUCTIONS A Elevated Operating Ambient If installed in a closed or multi unit rack...

Страница 14: ...lide completely from the outside portion of the rack slide 4 Set aside this inside portion of the rack slide You will be mounting this part of the rack slide to a side of the computer chassis later in...

Страница 15: ...s then you will need to use the optional rack frame mounting brackets 13 Attach the optional brackets to the rack slides as shown in figure 4 B and attach the completed assembly to the rack supports 1...

Страница 16: ...AC POWER The TRC4011 TVC4403 requires a single phase power source providing 110 240VAC at 50 to 60Hz to the AC input power outlet located at the rear of the chassis Power must be available at the thre...

Страница 17: ...age drives for the TRC4011 TVC4403 are designed for easy access Make sure you have a top chassis clearance of at least 6 152mm to remove or install system cards COOLING FANS The three cooling fans of...

Страница 18: ...ter located inside for cleaning or replacement POWER SUPPLY FIXED The 860W rear mounted fixed power supply option used in the TRC4011 TVC4403 rackmount computer is shown in the figure below Rear View...

Страница 19: ...correct type Dispose of used batteries according to the instructions PREPARATION FOR SHIPMENT The TRC4011 TVC4403 should always be removed from the rack cabinet if the unit must be shipped to another...

Страница 20: ......

Страница 21: ...e details ELECTRICAL Line Voltage 110 240VAC Line Frequency 50 60Hz Power Consumption 450W typical 800W or 860W max PHYSICAL Approximate Dimensions W x H x D 19 x 7 0 x 20 0 48 3cm x 17 8cm x 50 8cm N...

Страница 22: ......

Страница 23: ...TRC4011 TVC4403 Installation Guide 6 1 Trenton Systems Inc Chapter6 CE FCCPart15SubpartBCertificatesofCompliance TRC4011 000 CE Certificate of Compliance BXT7059 BPG7087 and Fixed PS Configuration...

Страница 24: ...TRC4011 TVC4403 Installation Guide Trenton Systems Inc 6 2 TRC4011 010 CE Certificate of Compliance JXT6966 BPG7087 and Fixed PS Configuration...

Страница 25: ...TRC4011 TVC4403 Installation Guide 6 3 Trenton Systems Inc TRC4011 020 CE Certificate of Compliance TSB7053 BPG7087 and Fixed PS Configuration...

Страница 26: ...TRC4011 TVC4403 Installation Guide Trenton Systems Inc 6 4 TRC4011 001 CE Certificate of Compliance BXT7059 BPG7087 and Redundant PS Configuration...

Страница 27: ...TRC4011 TVC4403 Installation Guide 6 5 Trenton Systems Inc TRC4011 011 CE Certificate of Compliance JXT6966 BPG7087 and Redundant PS Configuration...

Страница 28: ...TRC4011 TVC4403 Installation Guide Trenton Systems Inc 6 6 TRC4011 021 CE Certificate of Compliance TSB7053 BPG7087 and Redundant PS Configuration...

Страница 29: ...TRC4011 TVC4403 Installation Guide 6 7 Trenton Systems Inc TRC4011 000 FCC Part 15 Subpart B Certificate of Compliance BXT7059 BPG7087 and Fixed PS Configuration...

Страница 30: ...TRC4011 TVC4403 Installation Guide Trenton Systems Inc 6 8 TRC4011 010 FCC Part 15 Subpart B Certificate of Compliance JXT6966 BPG7087 and Fixed PS Configuration...

Страница 31: ...TRC4011 TVC4403 Installation Guide 6 9 Trenton Systems Inc TRC4011 020 FCC Part 15 Subpart B Certificate of Compliance TSB7053 BPG7087 and Fixed PS Configuration...

Страница 32: ...TRC4011 TVC4403 Installation Guide Trenton Systems Inc 6 10 TRC4011 001 FCC Part 15 Subpart B Certificate of Compliance BXT7059 BPG7087 and Redundant PS Configuration...

Страница 33: ...TRC4011 TVC4403 Installation Guide 6 11 Trenton Systems Inc TRC4011 011 FCC Part 15 Subpart B Certificate of Compliance JXT6966 BPG7087 and Redundant PS Configuration...

Страница 34: ...TRC4011 TVC4403 Installation Guide Trenton Systems Inc 6 12 TRC4011 021 FCC Part 15 Subpart B Certificate of Compliance TSB7053 BPG7087 and Redundant PS Configuration...

Отзывы: