TRC4011 / TVC4403 Installation Guide
Trenton Systems, Inc.
3-4
17.
You should hear and audible “click” when the rail stop hooks on the slide engage with the chassis
stops inside the rails mounted to the enclosure supports.
18.
Push up on the rail stop hooks and push the chassis completely into the enclosure.
19.
Each Trenton System chassis has two through holes on each chassis-mounting flange. Use these
holes to secure your chassis to the enclosure. (Note: The hardware used in this step is highly
dependent on your enclosure type; therefore, Trenton does not provide the hardware for this step.)
20.
Contact Trenton Systems if you require additional assistance.
C
ONNECTING
AC
P
OWER
The TRC4011 / TVC4403 requires a single-phase power source providing 110-240VAC at 50 to 60Hz to
the AC input power outlet located at the rear of the chassis. Power must be available at the three-pin AC
input receptacle located on the supply at the rear of the system. An over-current protection device shall
protect the power cord.
To connect AC power to the computer:
1.
Establish a chassis to earth ground connection to the TRC4011 / TVC4403 chassis.
or
2.
Connect the AC power cord(s) to the AC receptacle(s).
3.
Connect the plug end of the power cord(s) into the main outlet.
NOTE:
The maximum current limits for the +5V, +3.3V and +12V outputs from the system power supply
are 32A, 32A and 65A respectively. The system’s power monitoring circuits will shut the system down if
these maximum current limits are drawn from the power supply.
Figure 5 – Chassis Installat
ion