MBS1000 Installation Guide
4-1
Trenton Systems, Inc.
Chapter 4 - Replacing System Components
MBS1000
F
IELD
R
EPLACEMENT
U
NITS
(FRU
S
)
The MBS1000 is designed as a completely modular blade server. The server’s top cover should never be
removed in the field since all of the filed replacement units are accessible from either the front or rear of
the server chassis. However, a trained electronics technician is required to install or remove the
MBS1000’s FRUs and PCI Express plug-in option card.
NOTE:
When installing an option card into the MBS1000 modular blade server you must ensure that the
card installation does not result in non-conformance to the safety or EMC requirements for this product.
MBS1000 Field Replacement Units (FRUs)
Description
Trenton Systems P/N
IBM P/N
IBM FRU #
1
1U Rack Mount System w/o PS, IBM
262500003084-00
00RY451
N/A
2
1U Base System
198500001101-00
00RY465
3
MBC8240 SBC with Intel Xeon E3-1225v3, 32GB, Battery
198500001100-00
N/A
4
MBC8240 SBC with Intel Xeon E3-1225v3, w/o DIMMs, Battery
198500001110-00
00RY462
5
8GB DDR3-1600 ECC Memory DIMM
198500001112-00
00RY460
6
MBC8240 SBC Battery
198500001114-00
00RY455
7
900W 100-240VAC/200-250VDC System Power Supply
198500001098-00
00RR363
00RR365
8
750W -48VDC System Power Supply
198500001117-00
00RR406
00FX892
9
Fan Module
198500001102-00
00RY463
10
DVD with Carrier
198500001104-00
00RY461
11
2.5” HDD Carrier
198500001105-00
00RY471
12
1TB 2.5” SATAIII HDD with Carrier
198500001106-00
00RY459
13
Bezel, Fan Cover
198500001123-00
00RY464
14
26” System Slide Rail Kit
198500001127-00
00RY466
The design of the MBS1000 enables all FRUs to be accessed from either the front or rear of the modular
blade server. In the course of normal system maintenance in the field, there should never be a need to open
the modular blade server by removing the system’s top cover. Refer to the MBS1000 FRU table and the
figures below for each FRU location.
NOTE 1:
The system fans and drives are completely hot pluggable, and there is no need to
disconnect the MBS1000 incoming power connections.
NOTE 2: Trenton recommends disconnecting the MBS1000 incoming power connections before
removing the systems’ MBC8240 SBC. To remove power, disconnect the plug of the power
cord.
To remove all power from the equipment, disconnect power from both power supplies.
Table 1 – MBS1000 Field Replacement Units (FRUs)