(k) ** Equals the factor of uncertainty, which allows for variations in measurement and production. Vibration Data figures are tri-axial, which gives the
total vibration emission. Because of various factors, the range of vibration from these tools may vary between 2.4m/s
2
& 12.3m/s
2
. The vibration is
dependent on the task, the operators grip and feed force employed etc.
NOTE: The above vibration levels were obtained from tri-axial measurements to comply with the requirements of “The Control of Vibration at Work
Regulations 2005*” and the revisions to the (8662) now EN ISO 28927:2012 and EN ISO 20643:2005 series of standards. These values are at least
1.4 times larger than the values obtained from single axis measurements.
Based on European Union Council Directive 2002/44/EC (Physical Agents (Vibration) Directive)
This tool has been designed and produced in
accordance with the following directives:
TECHNICAL SPECIFICATIONS
Trelawny SPT Ltd
Trelawny House, 13 Highdown Road, Sydenham Industrial Estate, Leamington Spa, Warwickshire,
CV31 1XT, United Kingdom
Telephone: +44 (0)1926 883781
Fax: +44 (0)1926 450352
Email: [email protected]
Website: www.trelawnyspt.com
© TSPT UK 2011 Part No: 735.5255 issue 2
SURFACE PREPARATION TECHNOLOGY
All rights reserved. Any unauthorised use or copying of the contents or part thereof is prohibited.
This applies to trademarks, model denominations, part numbers and drawings.
Use only genuine Trelawny spares.
The use of non-Trelawny spare parts invalidates the warranty.
FAULT
CAUSE
ACTION
Engine stops suddenly or does
not run correctly
No fuel in the fuel tank.
Refuel fuel tank. (See safety section.)
Spark plug faulty.
Replace spark plug.
Fuel blockage.
Check fuel line and strainer.
Air cleaner blocked.
Replace air cleaner element.
Low oil level.
Rectify leaks and replenish oil.
Electric motor stops suddenly
Blown electrical supply fuse.
Replace fuse.
Motor overload protection activated
Disconnect electricity supply at mains and reset button inside starter box.
Electric motor will not start
Deadmans handle not engaged
Pull Deadmans level against handle bar and press start button.
Planer is slow or erratic
Drive Belt slack or failed teeth.
Replace Belts or adjust tension.
Worn Drum Cutters
Replace Cutters.
Surface too rough.
Use Trelawny TFP380 Planer to increase production.
Engine will not start
No fuel in the fuel tank.
Refuel fuel tank, see safety precautions.
Low oil level.
Rectify leaks, replenish oil.
Water in fuel.
Drain fuel tank, float chamber, and refuel.
Spark plug faulty.
Replace spark plug.
Engine will not turn over
Oil in Cylinder.
See page 2 - section.
Safety
.
Use above information in conjunction with the engine manufacturers Operation and Maintenance Manual.
If problem has not been cured by above actions, contact your local Trelawny agent or engine manufacturer for advice or rectification.
Trouble Shooting
Technical Specifications
Height
1080mm
42.5”
Width
480mm
19”
Length
1010mm
40”
Cutting width
240 mm
9.4 inch
Average depth of cut (concrete with no aggregate)
6mm
0.25 inch
Drum rpm approximately
1850 rpm petrol, 1750 rpm electric
Working distance from wall
75mm
3.0”
Weight
140 kg
308.5lbs
Power unit
8 hp Honda
5.96 kilowatt
Approximate Fuel Consumption
2.0 litre per hour
0.43 Gallon per hour
Power unit
7.5 hp Electric
415v 3ph 5.5kw
Noise L
WA
-
Declared noise emissions in accordance with BS ISO03744:2010 And
BS EN ISO 15744:2008
102.5dB (A)
Vibration (AEQ) - at the handle bar
Petrol engine version
8.8 m/s
2
(K= +40% -0%
Electric motor version
2.4 m/s
2
(K= +40% -0%
If your company has any problem with our products or would like to discuss the possibility of an
improvement being made to them, then please do not hesitate to contact us.
Your comments are both important and appreciated.
Содержание TFP260
Страница 1: ...TFP260 FLOOR PLANER OPERATION MAINTENANCE ...
Страница 6: ...STARTER BOX COMPONENTS AND WIRING DIAGRAM ...