background image

TFP260 FLOOR PLANER 

OPERATION & MAINTENANCE 

Содержание TFP260

Страница 1: ...TFP260 FLOOR PLANER OPERATION MAINTENANCE ...

Страница 2: ...e may produce smoke for a while from the exhaust but this should soon clear Finally stop the engine and recheck the engine oil level Ensure that the engine is level prior to carrying out this check If the engine oil level is low refill with the recommended motor oil see engine manufacturers operating instructions Risk of Hand arm Vibration injury These tools may cause Hand arm Vibration Syndrome i...

Страница 3: ... new machine the owner should first check that the power supply on site is suitable and adequate All cables should be fully uncoiled and never left wrapped around cable reels or tied in loops The starter box is fitted with a safety feature to protect the motor and relays from damage The starter boxes are preset and under no circumstances should they be tampered with stripped down or adjusted other...

Страница 4: ...belt adjusting bolts locking nuts Unscrew the adjuster bolts 39 to loosen the drive belt and then slide the toothed belt 34 off the drive pulley 28 Fit a new belt onto the pulleys as described above Adjust the belt tension using the belt adjusting bolts 39 and then tighten the locknut against the engine mounting plate ensure the belt tension is correct Do not over tighten Tighten all engine mounti...

Страница 5: ... 1006 Grease Nipple 15 326 9114 Lift Nut 70 326 06DW Double Web Drum 16mm shafts standard fit 16 326 9115 Side Plate Bearing Housing 326 060G Grooving drum 16mm shafts 17 326 9116 Drive Side Bearing Housing 326 1016DB Drum Complete D Web Beam 16mm shafts 18 326 9117 Outer Bearing Spacer 2 x required 326 1016DM Drum Complete D Web Milling 16mm shafts 19 326 9118 Inner Bearing Spacer 326 1016GT Groo...

Страница 6: ...STARTER BOX COMPONENTS AND WIRING DIAGRAM ...

Страница 7: ...l level Rectify leaks and replenish oil Electric motor stops suddenly Blown electrical supply fuse Replace fuse Motor overload protection activated Disconnect electricity supply at mains and reset button inside starter box Electric motor will not start Deadmans handle not engaged Pull Deadmans level against handle bar and press start button Planer is slow or erratic Drive Belt slack or failed teet...

Отзывы: