background image

OPERATION

 

Foreword

 

Thank  you  for  your  purchase  of  the 

TRELAWNY  Professional  use  A45 

ENDLESSBAG  Industrial  Vacuum 

Cleaner. 

 

 

This manual  contains  the  necessary 

maintenance  information  for  you  to 

ensure proper operation and care for 

this machine.

 

 

It  is  essential  for  you  to  read 

through this manuals thoroughly.

 

 

In  the  unlikely  event  that  you 

experience  problems  with  your  A45 

Vacuum,  please  do  not  hesitate  to 

contact your local Trelawny dealer or 

agent. 

We 

always 

welcome 

feedback  and  comments  from  our 

valued customers.

 

 

 

General Information

 

Before 

operating, 

performing 

maintenance  or  repairing  the  A45 

Industrial  Vacuum  Cleaner,  this 

manual 

must 

be 

read 

and 

understood by the operator, if in any 

doubt,  ask  your  supervisor  before 

using this equipment.

 

 

Local  safety  regulations  must  be 

followed at all times. Failure to follow 

these  instructions  could  result  in 

damage  to  the  A45  Vacuum  and/or 

personal injury. 

 

 

Trelawny  SPT  Limited  disclaims  all 

responsibility for damage to persons 

or objects arising as a consequence 

of incorrect handling of the machine, 

failure  to  inspect  the  machine  for 

damage  or  other  faults  that  may 

influence  the  operation  prior  to 

starting  work,  or failure  to  follow  the 

safety regulations listed or applicable 

to the job site.

 

This  machine  is  primarily  designed 

for the containment of nuisance dust 

and dust collection.

 

 

HEPA  filtered  vacuum  system  is 

available,  which  will  contain  99.97% 

(DOP)  of  all  air  borne  dust  when 

removing  toxic  or  contaminated 

products.

 

 

 It  can  be  used  both  indoors  and 

outside in dry weather only.

 

This  machine  is  not  water  proof, 

avoid splashing with water if using to 

collect fluid spills.

 

Safety

 

The person in charge of safety shall 

be responsible for informing workers 

about  the  risks  associated  with 

vacuum cleaner operations.

 

 

Train  operators  in  the  correct  use 

and  maintenance  of  the  vacuum  in 

order  to  protect  themselves  and 

others from hazards.

 

 

Failure  to  observe  basic  safety 

regulations  and  precautions  could 

cause  accidents  during  the  vacuum 

cleaners  operation,  maintenance  or 

repair. 

 

 

Trelawny 

shall 

under 

no 

circumstances  be  deemed  liable  for 

accidents or damage caused by use 

of  the  vacuum  cleaner  by  personnel 

not  properly  trained  or  who  use  it  in 

an improper manner.

 

 

The  safety  precautions  and  warning 

notices  are  indicated  in  this  manual 

and on the product.

 

 

Unless  these  hazard  messages  are 

heeded,  the  operator  could  become 

involved  in  accidents  with  serious 

consequences  for  him/herself  and 

others.

 

 

Trelawny cannot foresee all possible 

circumstances 

capable 

of 

representing  a  potential  hazard, 

therefore the warnings in this manual 

and  on  the  product  should  not  be 

deemed exhaustive.

 

 

 

Only  ever  use  original  Trelawny 

spare parts

 

 

Trelawny  declines  all  liability  in 

the  event  of  non

-

original  spare 

parts being used.

 

 

In  the  event  of  tools,  procedures  or 

work  methods  used  that  are  not 

explicitly recommended by Trelawny, 

ensure  no  hazards  exist  for  the 

operators and others.

 

 

 

 

 

Further  advice  is  available  from  our 

Technical Department.

 

The  employer  must  inform  and  train 

the  user  according  to  the  provisions 

of applicable local laws.

 

 

Before  using  the  machine,  prepare 

and  train  yourself  by  reading  this 

manual carefully.

 

 

Use of the machine by untrained and 

unauthorised persons is forbidden.

 

 

Do  not  use  the  machine  to  vacuum 

toxic  substances  unless  it  has  been 

equipped  with  the  special  filters 

required for the specific type of dust. 

 

 

Such  filters  must  be  explicitly 

requested by you.

 

 

Do  not 

vacuum flammable materials 

or  substances  or  which  could  cause 

explosions  (fuels,  solvents,  etc.).  To 

vacuum such materials, the machine 

must  be  built  with  anti

-

explosion 

motor  and  electric  system  and  this 

must be requested by you explicitly.

 

 

Do not vacuum corrosive substances 

unless the machine is equipped with 

containers  suitable  for  this  purpose 

(Stainless

-

steel AISI 304).

 

 

Use  of  the  machine  without  the 

supplied filters is not recommended.

 

 

If  the  machine  is  used  to  vacuum 

toxic/harmful 

substances, 

the 

ENDLESSBAG  section  must  be 

removed  and  the  filters  cleaned 

using  adequate 

P

ersonal 

P

rotection 

E

quipment.

 

 

This 

machines 

motor 

casing 

contains 

electrical 

components 

which must not be dismantled by the 

user.

 

 

When  using  the  machine,  be  aware 

of other people around you.

 

 

Use  the  machine  cautiously  on 

slopes  and  ramps.  Do  not  change 

direction on gradients. 

 

 

Make  sure  the  parked  machine 

remains  stable  by  operating  the 

braked wheel.

 

 

Do  not  open  the  vacuum  with  the 

motors running.

 

 

Содержание A45

Страница 1: ...A45 Industrial Dust Collector ENDLESSBAG Operation and Maintenance Manual www trelawnyspt co uk ...

Страница 2: ......

Страница 3: ......

Страница 4: ...s or damage caused by use of the vacuum cleaner by personnel not properly trained or who use it in an improper manner The safety precautions and warning notices are indicated in this manual and on the product Unless these hazard messages are heeded the operator could become involved in accidents with serious consequences for him herself and others Trelawny cannot foresee all possible circumstances...

Страница 5: ...lways quote the details shown on the vacuum cleaner serial plate To change the filter switch off the vacuum cleaner and remove the plug from the power socket release and remove the upper cap and then loosen nut A HEPA Filter Cartridge Class H 303 5274 Operation Warning The vacuum is heavy but it will move easily on flat ground If moving on any inclined ground take extreme care that control is not ...

Страница 6: ...e supplied connector on the pipe union Fit the supplied pipe in the connector Make sure the power supply corresponds to the voltage and frequency indicated on the vacuum cleaner plate IMPORTANT Do not plug in the power socket with wet hands In the event of an extension being used make sure this is in perfect condition in compliance with EC standards and with cable cross section suitable for the po...

Страница 7: ...is a vacuum meter indicating the degree of vacuum inside the vacuum cleaner If with the vacuum cleaner working and the vacuum inlet free the vacuum meter lever indicates an irregular depression level the filter will have to be shaken by means of the special lever Make sure the sealing gaskets of the motor head base and of the filter holder ring and of the Hopper are working efficiently The electri...

Страница 8: ... crushing hazard The Hopper locking operation must be performed by one person only who must lower the lever with both hands to lock the Hopper in position Replacing the filters To replace the filters proceed as follows Turn off the vacuum cleaner by pressing down the motor STOP switches Disconnect the vacuum cleaner plug from the power socket Ensure braked front wheel is locked Lift the lever that...

Страница 9: ...ermal magnetic switch tripped Reset the thermal magnetic switch Loose wiring incorrect voltage or blown fuse Check connections and power supply or replace fuse Dust is leaking out Perforated vacuum pipe Replace the pipe Perforated filter Replace the filter Filter unsuitable for type of job Fit a suitable filter for the type of material to be vacuumed The vacuum cleaner does not work as it should P...

Страница 10: ...CHINE Item Part No Description 1 303 5367 110v Motor Head Assembly 303 5366 230v Motor Head Assembly 2 303 5373 HEPA Filter Kit 3 303 5368 Filter Kit 4 303 5369 Chamber Kit 5 Frame Kit 6 303 3599 ENDLESSBAG Hopper Kit ...

Страница 11: ...EXPLODED VIEW MOTOR HEAD ...

Страница 12: ...equired 9 303 5131 Switch Rubber Covers 3 x required 31 303 5520 Bottom Valve Plate 3 x required 10 303 5245 Chrome Nut for Light 32 303 5525 Motor Bottom Plate 3 x required 11 303 5132 Red Light 33 303 5350 Motor Bottom Plate Gasket 3 x required 12 303 5178 Vacuum Gauge 34 303 5295 Base Plate Noise Damping Material 13 303 5157 Straight Pipe Coupling 35 303 5497 Master Motor Head Spacer 8 x requir...

Страница 13: ... Description 1 303 5289 Filter Gasket 2 303 5507 Filter Holding Ring 3 303 5493 Filter Clamp 4 303 5501 Filter Separator Cage 5 303 5264 14 Pocket G Polyester Filter 6 303 5502 Filter Shaker Cage 7 303 5503 Cage Pivot Pin 8 303 5581 R Clip ...

Страница 14: ... Adhesive Gasket 5 303 5500 Deflector 6 303 5305 Deflector Gasket 7 303 5499 Inlet Connector 8 303 5504 Spring 9 303 5506 Connector Latch 10 303 5508 Latch Pin 11 303 5491 Filter Shaker Handle 12 303 5492 Filter Shaker Lever Boot 13 303 5488 Filter Shaker Lever 14 303 5489 Filter Shaker Flange 15 303 4588 Canister Handle 16 303 5494 Left U Channel Mounting Bracket ...

Страница 15: ...o Description 1 303 5627 ENDLESSBAG Hopper 2 303 5347 O Ring 3 303 5355 Flap Gasket 4 303 5604 Flap 5 303 5584 Spring 6 303 5603 Flap Arm 7 303 5583 Container 8 303 5602 Knob 9 303 5605 Container Hanger 10 303 5770 ENDLESSBAG bag 4 x 20m ...

Страница 16: ...Fulcrum 5 303 5517 R H Cable Tie Holder 6 303 5597 ENDLESSBAG Support Plate 7 303 5513 Fastener Lever 8 303 5614 Frame Base 9 303 5430 Castor Wheel with Brake 10 303 5453 Caster Wheel Unbraked 11 303 5437 Axle Wheel Kit 12 303 5436 Wheel 13 303 5516 L H Cable Tie Holder 14 303 5519 Tube End Cap 15 303 5521 Push Handle ...

Страница 17: ...nt and appreciated All rights reserved Any unauthorised use or copying of the contents or part thereof is prohibited This applies to trademarks model denominations part numbers and drawings Use only genuine Trelawny spares The use of non Trelawny spare parts invalidates the warranty Model 110v 230v Power Watts 3000 3450 Vacuum rate Mm H2O 2 250 2 500 Max Air flow M3 h 525 540 Noise level dB A 76 7...

Страница 18: ...NOTES ...

Страница 19: ...NOTES ...

Страница 20: ...wn Road Sydenham Industrial Estate Leamington Spa Warwickshire CV31 1XT United Kingdom Telephone 44 0 1926 883781 Fax 44 0 1926 450352 Email sales trelawny co uk TSPT UK 2012 Part No 735 6050 issue 18 9 17 www trelawnyspt co uk ...

Отзывы: