FAULT FINDING
Machine storage
Remove the filter and clean it, empty the container and store the vacuum cleaner in a place protected against
condensation and at a temperature between 0°C and 40°C.
Cover with a nylon sheet to prevent accumulation of dust.
Scrapping
In case of scrapping, all the component parts of the vacuum cleaner will have to be disposed of through suitable
channels in accordance with applicable legislation.
Before scrapping, all plastic and rubber parts will have to be separated from the electrical material.
Most parts made from plastic, aluminium, copper or steel are suitable for recycling.
FAULT
CAUSE
ACTION
The cleaner fails to
start.
No power.
Check the power mains supply.
Check the integrity of the plug and power
cable. Check transformer rest button.
Indicator off and plug fitted, fuses burnt
out.
Replace the fuses.
Indicator on, plug fitted, switches working,
worn motor brushes
Replace the brushes.
Dust is leaking out
Perforated vacuum pipe.
Replace the pipe.
Perforated filter.
Replace the filter.
Filter unsuitable for type of job.
Fit a suitable filter for the type of material to be
vacuumed.
Pipe perforated or blocked.
Check the pipe and, if necessary replace.
The vacuum cleaner
does not work as it
should.
Container full
Empty container.
Filter blocked.
Replace filter.
Seals worn.
Clean the filter and if necessary change it.
Air leak.
Check for any air leaks out of closing
fasteners, tightening screws, container or filter
chamber.
If problem has not been cured by any of the above actions, contact your local Trelawny SPT dealership for assistance.