Pre-start check

 

Check  all  bolts  and  screws  for 
tightness.  Ensure  that  all  fittings  are 
secure. 
 
This  specific  vacuum  cleaner  model 
has  been  designed,  built  and 
protected  for  vacuuming  dusts  and 
solid materials only. SEE BELOW 
 
To  ensure  the  correct  operation  of 
the  vacuum  cleaner,  this  must  be 
positioned  protected  against 
atmospheric agents (rain, hail, snow, 
fog,  dusts  in  suspension,  etc.)  with 
a n   e n v i r o n m e n t a l   r u n n i n g 
temperature  between  5°C  and  45°C 
and relative humidity not above 70%. 
 
The  work  environment  must  be 
clean,  well-enough  lit  and  devoid  of 
an explosive atmosphere. 
The  vacuum  cleaner  must  not  be 
used  in  environments  containing 
substances in the form of liquids that 
could  vaporise  at  room  temperature 
and flammable dusts and gas. 
All  cables  should  be  fully  uncoiled 
and never left wrapped around cable 
reels or tied in loops.  
 
 

OPTIONAL FILTERS 

Besides  the  optional  HEPA  filter 
(303.5263),  and  depending  on  the 
dust to  be  vacuumed, the  following 
filters  and  accessories  are  also 
available: 

OPERATION 

Make  sure  the  maintenance 
engineer  has  carefully  read  the 
instructions contained in this manual 
and knows how the  vacuum cleaner 
works. 
 
Before  carrying  out  a  maintenance 
job, the maintenance engineer must: 
 

 

Disconnect  the  plug  from  the  power 
socket. 
 
Work  done  on  motors  or  other 
electrical component parts must only 
be  performed  by  a  specifically 
trained electrician. 
 
Always  use  tools  that  are  in  perfect 
condition  and  specifically  made  for 
the operation to be done. The use of 
unsuitable  tools  or  tools  not  in  good 
condition  could  cause  serious 
damage. 
 
 

Maintenance checks 

For  efficient  vacuum  cleaner 
operation,  a  number  of  checks  are 
best made periodically: 
 
Check  to  see  whether  the  filter  is 
worn or has become too permeable. 
 
Make sure the  gaskets of the motor 
head  base,  the  filter  holder  ring  and 
of the container are sealing correctly. 
 
The electrical parts (plugs, switches, 
cables, etc.) must not be faulty. 
 
The  screws  and  fastenings  must 
always be secure. 
 
Make  sure  the  container  is  not 
overfull.  
 
Check  the  integrity  of  the  flexible 
vacuum hose and accessories. 
 
If the flexible hose is perforated, the 
power of the cleaner will be reduced 
and  dust  may  leak  into  the 
environment. 
 
 
 
 
When  contacting  Trelawny  SPT  Ltd 
or  their  agents,  always  quote  the 
details  shown  on  the  vacuum 
cleaner serial plate. 

FLOOR PICKUP ATTACHMENT 

To  change  the  filter,  switch  off  the 
vacuum  cleaner  and  remove  the 
plug  from  the  power  socket,  release 
and remove the upper cap and then 
loosen nut (A) in picture below. 

The HEPA filter permits the trapping 
of  fine dust particles which have not 
been  contained  by  the  primary 
polyester filter. 
If  the  vacuum  cleaner  features  this 
specific filter, its filtering capacity will 
have to be periodically checked. 
 
Complete  HEPA Filter Kit. 
303.5377 
 

 
Antistatic filter 

For electrostatic dust.  

The bracket of the floor attachment 
must be secured to the vacuum 
cleaner frame by means of the 
special front mounting point (A). 

Remove the absolute filter, seal it in 
a  plastic  bag  and  dispose  of 
according to applicable local laws for 
the type of dust recovered. 

Содержание A22

Страница 1: ...A22 Industrial Dust Collector Bin Version Operation and Maintenance Manual www trelawnyspt co uk ...

Страница 2: ......

Страница 3: ......

Страница 4: ...he vacuum cleaner by personnel not properly trained or who use it in an improper manner The safety precautions and warning notices are indicated in this manual and on the product Unless these hazard messages are heeded the operator could become involved in accidents with serious consequences for him herself and others Trelawny cannot foresee all possible c ir c u m s t a n c e s c a p a b le o f r...

Страница 5: ...d specifically made for the operation to be done The use of unsuitable tools or tools not in good condition could cause serious damage Maintenance checks For efficient vacuum cleaner operation a number of checks are best made periodically Check to see whether the filter is worn or has become too permeable Make sure the gaskets of the motor head base the filter holder ring and of the container are ...

Страница 6: ...lance PVC brush PVC connection PVC extension a double bend and a flexible hose connection All other accessories must be specified and ordered separately Fit the supplied connector on the pipe union Fit the supplied pipe in the connector Make sure the power supply corresponds to the voltage and frequency indicated on the vacuum cleaner plate IMPORTANT Do not plug in the power socket with wet hands ...

Страница 7: ... the motors and allow a vacuum to be produced open the flap quickly and close the flap on the front of the vacuum several times the inrush of air produces the reverse pulse action If the orange light indicator is still on repeat the filter cleaning process If after this second cleaning process the orange light is still on and the vacuum cleaner is still inefficient replace all filters The filter c...

Страница 8: ...2 x 53 Height cm 107 Weight Kg 35 Important All material trapped and contained within the filter must be disposed of according to local legislation PART NUMBER DESCRIPTION 303 5275 M Cat Conical Cartridge Filter 303 5265 M Cat Anti Static Cartridge Filter 303 5280 PTFE Conical Cartridge Filter Loosen the screws on the shaft s bar remove the shaft and the filter s screws Remove the filter and loose...

Страница 9: ... mains supply Check the integrity of the plug and power cable Check transformer rest button Indicator off and plug fitted fuses burnt out Replace the fuses Indicator on plug fitted switches working worn motor brushes Replace the brushes Dust is leaking out Perforated vacuum pipe Replace the pipe Perforated filter Replace the filter Filter unsuitable for type of job Fit a suitable filter for the ty...

Страница 10: ...ad Assembly 303 5372 115V Motor Head Assembly 2 303 5390 Chamber Kit 3 303 5590 50mm dia Flap 4 303 5375 Machine Body Kit 5 303 5395 Dust Container Kit 6 303 5440 Wheel 2 x required 7 303 5430 Braked Castor Wheel 8 303 5460 Adapter Washer Castor Wheel 2 x required 9 303 5425 Castor Wheel ...

Страница 11: ...303 5275 M Cat Conical Cartridge Filter 303 5265 M Cat Anti Static Cartridge Filter 303 5280 PTFE Conical Cartridge Filter 3 303 5620 Filter Chamber with Flap 4 303 5495 Handle 5 303 5345 Inlet Gasket 6 303 5505 Locking Pin 7 303 5570 Inlet 8 303 5600 Vacuum PVC Cap 9 303 5365 Adhesive Gasket ...

Страница 12: ...EXPLODED VIEW CONTAINER ITEM No PART NUMBER DESCRIPTION 1 303 5625 Container 2 303 5475 Handle 2 x required 3 303 5450 Castor Wheel 3 x required 4 303 5470 Adapter Washer for Castor Wheel 3 x required ...

Страница 13: ...o PART NUMBER DESCRIPTION 1 303 5610 Trolley 2 303 5420 Round head screw 4 x required 3 303 5410 Galvanized toothed washer 4 x required 4 303 5560 Lever Fulcrum 2 x required 5 303 5555 Lever spacer 2 x required 6 303 5545 Lever ...

Страница 14: ...EXPLODED VIEW ELECTRIC MOTOR ...

Страница 15: ... Light 12 303 5165 Green Light 13 303 5330 Side Cover Noise Suppressing Material 14 303 5315 Cover Noise Suppressing 15 303 7575 110v PU Pipe 303 5215 230v Nylon Pipe 16 303 5260 Black Cable 17 303 5175 Pressure Sensor 18 303 5335 Motor Fastener Suppressing Material 19 303 5115 Motor Mounting Plate 20 303 5320 Motor Fastener Noise Suppression Material 2 x required 21 303 5300 Gasket 4 x required 2...

Страница 16: ...own Road Sydenham Industrial Estate Leamington Spa Warwickshire CV31 1XT United Kingdom Telephone 44 0 1926 883781 Fax 44 0 1926 450352 Email sales trelawny co uk TSPT UK 2017 Part No 735 6015 issue 5 4 17 www trelawnyspt co uk ...

Отзывы: