![Trek II SSP-3A-1 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/trek-ii/ssp-3a-1/ssp-3a-1_quick-stark-manual_1155270005.webp)
Although standard Hammond tone cabinets or Leslie model 122s are recommended, many other successful output
configurations are possible. When using one of the Leslies listed below, mount the appropriate receptacle in the organ outlet
box and wire as shown.
____________________________________________________________________________________________________
OUTLET WIRING FOR LESLIE MODELS:
122XB, 315, 330, 415, 422, 615, 715, 716, 722, 723, 740, 750, 771, 815, 820, 822, 840, 860, 912, 914
____________________________________________________________________________________________________
OUTLET WIRING FOR LESLIE MODELS:
760, 770, 900, 910, 925
____________________________________________________________________________________________________
ADDITIONAL OUTPUT CONFIGURATIONS
-5-
TREMOLO
TS-2 (OR OTHER) TREMOLO SWITCH
CHORALE
78S9 SOCKET
(REAR VIEW)
78S11 SOCKET
(REAR VIEW)
1
2
3
4
5
6
7
8
9
VIOLET
WHITE
BLACK
INSULATE WITH HEAT SHRINK TUBING
RED
BROWN
GROUND
G4 (SIGNAL)
PRE-AMP
TERMINALS
GREY
BLUE
SWITCHED
AC LINE
1 2
3
4
5
6
7
8
9
10
11
TREMOLO
TS-2 (OR OTHER) TREMOLO SWITCH
CHORALE
GROUND
G4 (SIGNAL)
PRE-AMP
TERMINALS
RED
BROWN
VIOLET
WHITE
BLACK
GY/WHITE
RY (RELAY)