D. To Connect Hose to Pail / Drum with the Y-
Connector
1. Connect a hose to Y-connector by using a small amount of lube
on the barb and pushing the hose onto the barb.
2. Push the hose all the way to shoulder of the barbed fitting.
3. Clamps should be used on all connections.
Figure 7-H
E. To Connect Hose to Pail / Drum with a Manifold
1. Remove NPT plugs from manifold fittings and install the check
valve assembly for the desired number of lines.
2. Install the hose from the pail / drum to the end of the check
valve assembly (see Figure 7-I).
3. Clamps should be used on all connections.
Figure 7-I
15
OM-MF4-1.1