_INSTALLATION
Page 10
Each tub is individually tested in the company
to guarantee its perfect operation.
During this phase of the installation, you must
test the product to ensure that all adjustments
made in the company have been maintained.
Due to improper transport and installation,
slight leak problems may arise occasionally.
In the event of leaks, on the lower part or along
the edge near the closure handle, given the
certainty of state-of-the-art assembly as
previously described, work on the shape of the
tub by opening and closing the front side
.
To do this, on the frame at the centre front,
there is an upright with adjustable head
consisting of a plate with threaded rod screwed
onto the tub and by two nuts, one on front and
one on the rear side.
This system is able to slightly modify the
closing layout.
A)
Base leak
: it will be necessary to screw in
the rear nut on the riser bringing it to stop on
the plate assembled on the tub. Screw in the
external nut a half a rotation at a time until the
leak is resolved. Tighten the rear nut again on
the riser. This operation allows us to open the
front side.
B)
Leak on top lateral side:
you will need to
unscrew by half a turn to the front nut to the
upright and do the same on the rear nut until
you fix the leak. With this operation you have
closed the front side
ATTENTION
The regulations will be minimal to avoid
compromising tightness.
At the end of each adjustment, the two nuts
must be firmly tightened to the upright.
Middle upright
Plate
Front and rear
nut adjustment