PAGE 22
MEGA 120D PUMP OPERATION / MAINTENANCE MANUAL
Figure 4-8
•
Install shaft bushing per Figure 4-8.
•
Install locking ring until flush with fluid cavity face and resistance is met.
•
Tighten until next available notch aligns with locking screw hole, check to assure that
the shaft bushing does not move.
•
Insert locking screw into hole and tighten until flush with locking ring.
•
Thread one push plate onto shaft until push plate bottoms out on shaft shoulder.
•
Tighten push plate to 48 oz.-in, and then rotate CW until locking screw hole is
aligned with the next available hole in shaft. The first push plate can be visually
aligned separate from the body.
•
Install push plate locking screw. Tighten to 12 oz.-in.