![TREBING + HIMSTEDT SPI 3 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/trebing-himstedt/spi-3/spi-3_manual_1154873038.webp)
Appendix
38
Trebing & Himstedt | SPI 3 | MODBUS RTU
Function 02: Read Input Status
Function 03: Read Holding Register
Function 04: Read Input Register
Request to the slave
Slave response
Byte
Contents
Hex code (e.g.)
Contents
Hex code (e.g.)
Byte 1
Slave Address
11
Slave Address
11
Byte 2
Function
02
Function
02
Byte 3
Starting Address High
00
Byte Count
03
Byte 4
Starting Address Low
C4
Data (Inputs 10204-10197)
AC
Byte 5
No. of Points High
00
Data (Inputs 10212-10105)
DB
Byte 6
No. of Points Low
16
Data (Inputs 10218-10113)
35
Request to the slave
Slave response
Byte
Contents
Hex code (e.g.)
Contents
Hex code (e.g.)
Byte 1
Slave Address
11
Slave Address
11
Byte 2
Function
03
Function
03
Byte 3
Starting Address High
00
Byte Count
06
Byte 4
Starting Address Low
6B
Data High (Register 40108)
02
Byte 5
No. of Points High
00
Data Low (Register 40108)
2B
Byte 6
No. of Points Low
03
Data High (Register 40109)
00
Byte 7
–
–
Data Low (Register 40109)
00
Byte 8
–
–
Data High (Register 40110)
00
Byte 9
–
–
Data Low (Register 40110)
64
Request to the slave
Slave response
Byte
Contents
Hex code (e.g.)
Contents
Hex code (e.g.)
Byte 1
Slave Address
11
Slave Address
11
Byte 2
Function
04
Function
04
Byte 3
Starting Address High
00
Byte Count
02
Byte 4
Starting Address Low
08
Data High (Register 30009)
00
Byte 5
No. of Points High
00
Data Low (Register 30009)
0A
Byte 6
No. of Points Low
01
–
–