![TRAXX P8000 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/traxx/p8000/p8000_operation-manual_1154278008.webp)
8
3 Phase Power:
Ideally, the power converter should be supplied with 380V to 480V three phase power for maximum
performance. If the plug does not match the available outlet, a suitable plug can be mounted by a qualified
electrician.
Single Phase Power
In situations where 3 phase power is not available, this machine may also be run on 220V to 240V single phase
power with slightly reduced power. Use the single phase adaptor cable. Using the single phase adaptor cable,
the current is limited to 16A.
If more power is needed, and a 32A or larger breaker is available, the main plug may be removed, and the
converter's main power supply cable may be directly wired to the breaker. In this case, connect the L1 and
L2 wires to the breaker, leaving the L3 wire unconnected. Then connect the earth (ground) wire to the earth
connection.
NOTE: The above action may only be performed by a qualified electrician.
Power Supply Connections: Three Phase and Single Phase
CEE 16A 480V
3P + N + E
CONNECTOR
1
Ø~ ADAPTOR
CABLE
2P + E
1
Ø~ 220V - 240V
CEE 16A 480V
3P + N + E
PLUG
CONVERTER
3
Ø
~
380V
-
480V
CEE 16A 480V
3P + N + E
PLUG
CONVERTER
L1
L2
L3
PE
N
L/+
N
PE
BROWN
BLUE
BROWN
BLACK
GREY
GREEN / YELLOW
L1
L2
L3
PE
N
1
Ø~ 220V - 240V
3
Ø~ 380V - 480V
1
Ø~ 220V Adaptor Cable
CEE 16A 5P
Female Connector
CEE 16A 5P
Male Plug
Converter Supply Cable
GREEN / YELLOW
R16 High Frequency Ring Saw & P8000 Power Converter
Operations Manual | 7