![TRAXX P8000 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/traxx/p8000/p8000_operation-manual_1154278011.webp)
R16 High Frequency Ring Saw & P8000 Power Converter
Operations Manual | 10
Inspect the blade before use. It must not be cracked, warped or damaged in any way that would cause a hazard
in operation. Loose diamond segments can be ejected at high speed, causing possible injury. Always check
that the diamond segments are not under cut. If the diamond segments are thinner or nearly thinner than the
blade core, the kerf will be too tight fitting and could easily lead to kickback.
Inspect the blades for segment damage, arbor hole damage or any other damage which could cause hazardous
operation.
SPLASH GUARDS
The spring-loaded splash guards are useful to help contain slurry which splashes toward the back. The upper
guard has an over-center spring which will lock into the fully open position if it is pulled all the way back. The
lower guard has a clip which can be used to lock the guard in the fully open position.
WATER CONNECTION
Water is a basic requirement for this tool and is essential for cooling
of the motor and converter. The water also serves as a coolant
to avoid the working surface of the diamond segments from
overheating. Water also keeps down dust and flushes away abrasive
particles.
The converter has 2 water connections. Connect the water supply to
either connection on the converter first and then connect the other connection to the motor using the water
coupling hose.
CAUTION: NEVER OPERATE THIS TOOL WITHOUT WATER FLOW THROUGH BOTH THE CONVERTER AND
THE MOTOR.
It is designed to be water cooled and would quickly overheat without water.
WARNING: Check all connections of the water feed system to ensure there are no leaks. Inspect hoses
and other critical parts which could deteriorate.
WARNING: The maximum water pressure should not exceed 70 psi (4 bar).
Note: Use a wet vacuum to collect cooling water if nearby objects
could be damaged by water.
WATER FEED VALVE
The water flow is controlled by the water feed valve. The water to the
blade may be finely adjusted to the required amount.
Inlet Connection
Open
Closed
Water Feed
Valve