In-rush current @ 120V
Description
1 Fixture
2 Fixtures
3 Fixtures
…
n Fixtures
Present time
ProPoint Vista 100W
30A
60A
90A
…
n*30A
0.38ms
ProPoint Vista 2x100W (200W)
60A
120A
180A
…
n*60A
0.38ms
ProPoint Vista 3x100W (300W)
90A
180A
270A
…
n*90A
0.38ms
Description
In-rush current @ 230V
Description
1 Fixture
2 Fixtures
3 Fixtures
…
n Fixtures
Present time
ProPoint Vista 100W
60A
120A
180A
…
n*60A
0.38ms
ProPoint Vista 2x100W (200W)
120A
240A
360A
…
n*120A
0.38ms
ProPoint Vista 3x100W (300W)
180A
360A
540A
…
n*180A
0.38ms
1.6 Additional Accessories
Termination Kit
A ProPoint termination kit (part number AM243520054) may be purchased separately. This kit contains the
following components:
- (6) Splicing wire connectors: For use in connecting data cable conductors. See section 3.2 for additional
information on usage.
NOTE
Wire nuts are not permissible for use with data connections and will void warranty.
- 120 Ohm resistor for use in terminating the DMX512 data line at the last luminaire. See section 2.6
for additional information on usage.
FIG.7: ProPoint Termination Kit