9 of 13
Item Code
Description
AM412960055
PX RIBBON SEALING GLUE 100ML
AM412970055
PX RIBBON VB FIELDCUT ENDCAP 20PC
AM412980055
PX RIBBON HB FIELDCUT ENDCAP 20PC
AM412990055
PX RIBBON FLAT FIELDCUT ENDCAP 20PC
For VB / HB:
•
Place the Ribbon VB / HB on the cutting tool, with the window of the body facing upward.
For Flat:
•
Place the Ribbon Flat on the cutting tool, the LED should face upward.
•
Avoid contact of the silicone body with the cutter edge when the cutting position is not in
place to avoid damage of silicone body.
•
The Ribbon should be placed perpendicular to the cutting edge to make sure the cut
surface is not tilted.
•
The cut surface should be flush and smooth.
FIG.8: LED Strip Sealing
RTV
• After cutting, the Field-Cut End Cap should be used with the RTV PX Ribbon
Sealing Glue applied on the cut end.
• The sealing should be done at least 1-2 days at room condition (temperature
25degC & relative humidity 55%) before on-site installation to allow complete
curing of silicone.
Procedure
• Fill the End Cap with Sealing Glue completely.