To prematurely end the length of a string of Dots, the optional Field-Cut End Cap should
be used with DOW CORNING 7091 Silicone Sealant applied on open-ended cable. This
should be done at least 1-2 days at Room Condition (Temperature: 22°C & Relative Humidity:
50%RH) before on-site installation to allow curing of silicone.
FIG.13: Field-Cut Sealing Procedures
Terminate cable with a straight
cut. Apply and fill 7091 silicone (not
included) on open-ended cable
(make the glue is about 1mm higher
than the height of the cable).
1
Insert the flat cable with glue
into the bottom of the silicone
sleeve.
2
3
Clean excess silicone from end
cap.
The end edge of the silicone
sleeve should rest against the
inner bottom of the end cover.
4
Fix the flat cable waterproof end
cover with screws (M3*6.0mm), and
electric screwdriver torque required
0.5-0.6N.m.
5
6
Place on flat surface for the cure
time recommended by 7091
silicone’s instruction.