background image

www.traxontechnologies.com

©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. 
PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Installation Guide

06/19 V1.1

12 of 21

www.traxontechnologies.com

©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. 
PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Installation Guide

06/19 V1.1

13 of 21

2.3.2  

Mounting Allegro Dot M/L

1.  Allegro Dot M/L must be mounted without any stress induced at the boundary area of 

the cable and Allegro Dot. 

2.  Allegro Dots MUST be mounted to the installation surface via the mounting holes, either 

by screw or cable tie.

FIG.13:  Mounting the Allegro Dot M/L

(M3 Screws not included)

Suggested alternative method 

if M3 screws are not viable

(Cable ties not included)

 

(M3 Screws not included)

Suggested alternative method 

if M3 screws are not viable

(Cable ties not included)

3.  Cable segment must not be bent below 20mm from the housing of the Allegro Dot M/L 

and cable overmold (Minimum Bending Length).

4.  Secure the cables between Allegro Dot M/L (every 500mm, using cable tie) and create a 

small clearance beneath the cable (see below diagram). Ensure no damage is generated 
on the cable. 

FIG.14:  Securing the cable

 

Observe clearance 

Cable tie

Mounting surface

2.3  On-Site Installation

• 

DO NOT attempt installation in wet or severe weather conditions.

• 

DO NOT leave and expose any Allegro Dot M/L, Pixel Distributor or LED 

Engine unconnected under wet/raining or snowing environment.

• 

Ensure all the cable connectors of Allegro Dot M/L are removed from the 

Pixel Distributors before installing.

• 

DO NOT pull on cable of Allegro Dot M/L. IP failure induced by stressed/

damaged cables during or after installation will not be under warranty by 
Traxon Technologies.

• 

ALWAYS keep the cables protected from sharp objects and ensure no 

damage is generated on the cable.

• 

Failure to keep Allegro Dot M/L within the operating temperature range of 

-30°C to +60°C (+50°C for North America), -22°F to +140°F (+122°F for 
North America), and storage temperature range of –40°C to 70°C (–40°F 
to 158°F) will void the product’s warranty.

2.3.1  

Mounting LED Engine

1.  Fix LED Engine on top of Pixel Distributor with included M4 screws.  

NOTE: Keep adjacent LED Engines and Pixel Distributors a minimum 150mm (5.91”) 
apart for better heat dissipation.

FIG.12:  Mounting LED Engine on top of Pixel Distributor

LED Engine mounts
on top of the Pixel Distributor

M4 × 8mm × 4

(Included)

(Not included)

M5 anchor bolts

(LED Engine is ordered 
separately)
Mount Pixel Distributor
with connectors facing down

 

150mm/5.91”

clearance

150mm/5.91”

clearance

150mm/5.91”

clearance

150mm/5.91”

clearance

150mm/5.91”

clearance

150mm/5.91”

clearance

2.  Mount the Pixel Distributor with 4 × M5 Anchor Bolts (not included). Recommended 

orientation is with connectors facing DOWN (see above diagram).

Содержание Allegro Dot L

Страница 1: ...Allegro Dot M L INSTALLATION GUIDE V1 1 Cover Allegro Dot M L Direct View Allegro Dot M L Diffused View ...

Страница 2: ...dots are single dot controllable by DMX RDM e pix or Ethernet making this durable scalable solution equally ideal for vivid accent text graphics and video replay in installations of any size and complexity Each string is connected via the Allegro Dot Pixel Distributor which can be easily configurable by RDM to form large installations The IP66 and IP67 rated UV resistant cover and aluminium casing...

Страница 3: ...TENTS E U PATENTS JAPAN PATENTS OTHER PATENTS PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide 06 19 V1 1 5 of 21 FIG 3 Allegro Dot M L String 1 2 Dimensions FIG 1 Allegro Dot M L Direct View FIG 2 Allegro Dot M L Diffused View 44mm 1 7 52mm 2 Ø60mm 2 4 68mm 2 8 Ø 3 9m m 0 15 x 2 1 7 m m 0 7 Ø60mm 2 4 1 5 1 m m 0 6 Ø 4 m m 0 2 7 7mm 0 3 1mm 0 03 Detail A scale 2 1 68m...

Страница 4: ...TENTS JAPAN PATENTS OTHER PATENTS PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide 06 19 V1 1 7 of 21 1 5 Packing Contents FIG 6 Allegro Dot M L Packing Contents FIG 7 Allegro Dot M L Distributor Packing Contents 4 x Screws PSU Mounting Allegro Dot M L Pixel Distributor 1 3 Pixel Distributor FIG 4 Allegro Dot M L Pixel Distributor 244 2mm 9 6 224mm 8 8 20mm 0 79 9mm 0...

Страница 5: ... Allow slack on cable to reduce stress 2 INSTALLATION 2 1 Points To Consider Plan your installation before mounting any luminaires The following should be considered for a successful installation Weather conditions and ambient temperature of installation site Appropriate cable lengths Adequate space for better heat dissipation 150mm apart of LED Engines see 2 3 On Site Installation on page 12 Appr...

Страница 6: ...ice DO NOT attempt to install Allegro Dot M L with functional defects on site 2 2 3 Requirements Of Cable Bending And Twisting Please take EXTRA precautions before bending or twisting Allegro Dot M L cable X lock Lead Cable must NOT be bent below the Minimum Bending Radius 4x Cable Diameter and the Non Bendable Length of 50mm near the connector end or near the cable overmold MUST be adhered to FIG...

Страница 7: ...4 Securing the cable Observe clearance Cable tie Mounting surface 2 3 On Site Installation DO NOT attempt installation in wet or severe weather conditions DO NOT leave and expose any Allegro Dot M L Pixel Distributor or LED Engine unconnected under wet raining or snowing environment Ensure all the cable connectors of Allegro Dot M L are removed from the Pixel Distributors before installing DO NOT ...

Страница 8: ...within the specified temperature range Refer to 6 TECHNICAL SPECIFICATION for more details 6 Do not attempt to open the product Not user serviceable 7 Do not use the product if any part of it or the power cables are damaged 8 Only use product for specified voltage do not exceed Refer to 6 TECHNICAL SPECIFICATION for more details 9 Always maintain connection to ensure waterproofing 10 If the produc...

Страница 9: ... Cable B TX Connect Data Bridge Indoor Outdoor Cable 5m Maximum 50m TX Connect Data Outdoor Cable 0 6m 2ft or 3m 10ft available Cable C Dot RGB RGBW M 3 2 L 4 3 M 13 10 L 15 12 DMX e pix Outdoor cable specification CAT 5e UTP FTP PVC jacket UV resistant Outer diameter 6mm 0 24 Filled type The warranty will void if in use cable is not follow the specification of outdoor cable FIG 17 System Diagram ...

Страница 10: ...l Contact your local Traxon office or distributor for details If the product is not working as specified please contact your nearest authorized service center or Traxon Technologies office for assistance 6 TECHNICAL SPECIFICATION Model Allegro Dot M Direct View Allegro Dot M Diffused View Allegro Dot L Direct View Allegro Dot L Diffused View Color Range 16 7 Million additive RGB colors white CCT 6...

Страница 11: ...s are connected with proper polarity Shadowing Light source covered Adjust pitch between Allegro Dot M L strings Check for cables wires or unwanted debris covering LED light source Modules are dim Excess products connected Ensure the power supplies are not overloaded due to an excess of products connected Flickering Incorrect power input Excess products connected Ensure the input voltage is correc...