ADDENDUM #3 Interior Masonry Chimney Conversions
¥ Follow the requirements and use the equipment listed in the illustration to the right to install this
appliance into an interior masonry chimney.
¥ Maximum vertical rise is 30'
¥ Minimum vertical rise is 10'
¥ Use the following restrictor positions:
Position 7 for heights between 10' (3 M) and 24' (7.3 M)
Position 5 for heights between 24' (7.3 M) and 30' (9.1 M)
NOTE
: these restrictor positions are based upon lab tests. The ideal restrictor position may vary
slightly.