![Travis Industries Small Flush Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/travis-industries/small-flush/small-flush_owners-manual_1154140017.webp)
Fireplace
Insert
Installation
(for qualified installers only)
17
© Travis Industries
100-01342
4131101
Vent Overview
This insert utilizes a catalytic combustor to increase efficiency and decrease emissions. This increases
the air resistance inside the firebox, making the flue connection especially important. To insure proper
draft, and to prevent smoke spillage during re-loading,
it is crucial for the flue to be sealed
. Use the
included gasket to seal the liner connector to the flue adapter.
In addition, we recommend using non-combustible fiberglass insulation to seal the fireplace enclosure.
By sealing the top and bottom of the chimney, and the surround panels, you will be ensuring outside air is
not pulled into the chimney.
The liner must be stainless
steel connector or flexible vent.
Follow the liner manufacturer's
insturctions for installation and
support.
Remove damper or wire it open
Airtight Insulated
Clean-Out
Combustible Mantle
Flue Liner
See the section "Insert
Placement Requirements" for
minimum clearances and
hearth required.
Cap (prevents water from
entering)
Install a non-combustible
cover plate to prevent water
from entering the chimney
Seal the flue connection with the
included gasket.
We recommend using non-combustible
fiberglass insulation to seal the fireplace
enclosure (chimney top and bottom, and