10
Installation (for qualified installers only)
© Travis Industries
4120301
100-01286_000
Factory-Built (Metal) Wood-Burning Fireplace Requirements
NOTE
: Any parts that are removed must be removed in a way that would allow them to be re-installed if
the insert is ever removed (removal of rivets or screws is acceptable).
The damper ("A") and grate (with log set) ("B") must be removed (see the illustration below)
The smoke shelf ("C"), internal baffles ("D"), screen ("E"), masonry lining or refractory ("G" & "I"), and
metal or glass doors ("F") may be removed (if applicable)
The fireplace must be permanently marked to
indicate that it has been altered and is no longer
suitable for burning solid fuel (wood), unless the
removed parts are re-installed. Cutting of any
sheet metal parts or glass is prohibited.
The insulation ("H"), and any structured rigid frame
members must not be removed or altered (side and
top of door frame, side and top of the face of the
fireplace, metal sides, etc.).
The metal floor ("J") may be removed to allow
additional room for installation of the insert. If the
floor is removed the insert must be placed directly
on the metal base of the metal fireplace.
The surround panels should not seal ventilation
openings on the fireplace.
If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 inch (37.5 mm) or
less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner.
This access hole must be plugged with non-combustible insulation after the gas supply line has been
installed.
Fireplace Altered Tag
Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable
method). You may wish to place it in a location where it will be covered by the surround panels.
Hearth Requirements
The heater and face must not contact combustible surfaces. A non-combustible hearth extension is not
required. However, if the heater is installed next to the floor, we recommend a hearth to protect the
flooring surface from discoloration or other negative impact from the heater.
C
B
F
I
D
E
A
G
H
J