30 Operation
© Travis Industries
4120301
100-01286_000
Accent Light
This heater has a built-in accent
light that may be turned on and off
and dimmed to your preference.
Turn the knob to achieve the
desired light output.
Continuous/Intermittent Pilot Switch
This heater may run with the pilot continuously running or in intermittent
mode. For most homeowners, the intermittent mode is preferred (this
saves fuel, doesn’t give off un-needed heat). However, in some situations
the homeowner may prefer to switch the heater to continuous pilot. The
most typical reasons for switching to continuous pilot are:
Very Cold Conditions – in very cold conditions you may notice that the burner does not light quickly,
and the flames lift off the burner. If this is situation, we recommend you switch to continuous pilot.
This will create a slight draft in the vent, allowing for the burner to light quickly and draft correctly.
Excessive Condensation on Glass After Startup – certain installations may encounter excessive
fogging on the window after startup (not just the first time the heater was started). This is an
aesthetic condition that may be remedied by switching the heater to continuous pilot.
Cold Glass or Heater Front – in very cold conditions you may notice that the heater front and glass
become very cold. To remedy this, switch the heater to continuous pilot.
Frequent On / Off Operation – if you are frequently turning the heater on and off, you may wish to
leave it in continuous pilot. This allows the burner to turn on more quickly, without pilot ignition delay.
ACCENT LIGHT
OFF
HIGH
LOW
OFF
LOW
HIGH