P
AGE
8
I
NSERT
I
NSTALLATION
(C
ONT
.)
M
ASONRY
F
IREPLACE
R
EQUIREMENTS
¥
Chimney must have a clay tile liner or a stainless steel liner (positive connection)
¥
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be
repaired prior to installation of the insert
¥
Chimney height: 15' minimum; 33' maximum.
¥
Entire fireplace, including chimney, must meet local building requirements
Drafting
Performance
This appliance relies upon natural draft to operate. External forces, such as wind,
barometric pressure, topography, or factors of the home (negative pressure from exhaust
fans, chimneys, air infiltration, etc.), may adversely affect draft. Travis Industries can
not be responsible for external forces leading to less than optimal performance.
L
EVELING
B
OLT
I
NSTALLATION
Inside the accessory pack are a pair of leveling bolts used to level the insert if the fireplace has a
stepped-up hearth. To install, raise the rear of the insert up and insert the leveling bolts into the holes in
the rear corners of the insert. Screw the bolts down until they extend the same height as the hearth steps
up. After the insert is installed, fine-tune the leveling bolts to level the insert (see the illustration below).
This distance is the
hearth step-up.
The leveling bolts
should stick out
this far from the
base of the insert.
Fireplace
Hearth
The leveling bolts
go into the holes in
the outer rear of the
insert baseplate.
B
LOWER
I
NSTALLATION
The included blower is fragile and should be installed last (see directions below).
Control Box
Remove the two screws
here with a 3/8" nutdriver.
Plug the
blower
into a
110 volt
grounded
outlet.
Replace the two screws
and tighten.
Center the blower
underneath the ashlip. Lift
up on the blower so it tucks
up underneath the ashlip.
1.
4.
3.
2.