Travis Industries DVS GSR NB Скачать руководство пользователя страница 37

 Maintenance 

37 

© Travis Industries 

4120228 

100-01285_000 

Accent Light Replacement  

An accent light is included in your heater to provide additional lighting.  This bulb will burn out over time.  
To replace, follow the directions below: 

 

Shut off gas to the heater and let it cool for 15 minutes.  

 

 

Remove the glass (see page 22) and logs.

 

 

Replace the halogen bulb with the following bulb: 
 (

NOTE

: .Take care to not touch the bulb with your fingers – use foam packing or paper towel to hold the bulb):

 

35 Watt 120 Volt T4 Halogen Bulb (G6.35 Base)

 

 

Yearly Service Procedure 

 

Failure to inspect and maintain the heater may lead to improper combustion and a potentially dangerous 
situation.  We recommend the following procedures be done by a qualified technician.

 

1.  Turn the pilot flame to continuous.  It should touch approximately 3/8" of the top of the flame sensor.  If it does 

not, contact your dealer for service. 

2.  Shut off gas to the heater and let it cool for 15 minutes.  Remove the glass (see page 22). Glass may be cleaned 

with glass cleaner and a soft cloth (do not use abrasive cleaners). 

3.  Remove the log set (

NOTE: the logs are very fragile

).  If severely deteriorated, replace.  Check the logs for 

sooting.  A small amount of soot along the bottom of the logs is normal.  If excessive sooting is found, the heater 
will require adjustment.  Contact your dealer. 

4.  Inspect the burner and remove any debris. 

 

Make sure the burner is not warped, cracked, or damaged.   

 

Check the firebox and area around the pilot to make sure there is no warping or damage. 

 

If any problem is found, discontinue use and contact your dealer for service. 

5.  Replace the log set.  Clean and replace the glass.  If the glass is damaged, replace.  Make sure the gasket along 

the perimeter of the glass contacts the face of the firebox and forms an air-tight seal.  If it does not, re-align or 
replace the gasket to insure an air-tight seal.   

6.  Inspect the area behind the access door.  Clean if necessary.  Check the gas 

control valve and the gas lines.  If damage is found, discontinue use and contact 
your dealer for service.  Clean the air channels, ducts, and blower. 

7.  Start the main burner.  Inspect the main burner and pilot flame.  After 15 minutes 

the flames should be orange/yellow and not touch the top of the firebox.  If the 
pilot or main burners do not burn correctly, contact your dealer for service.  
Monitor blower operation.   

8.  Remove any debris or vegetation near the vent termination.  Contact your dealer 

if any sooting or deterioration is found near the vent termination.  Venting system 
should be examined by a qualified agency. 

Содержание DVS GSR NB

Страница 1: ...hone in your building Immediately call gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and servi...

Страница 2: ...Insert has the same serial number as yours The serial number is attached to the appliance near the gas control valve This serial number will be needed in case you require service of any type Model DV...

Страница 3: ...Panel 21 Routing the Power Cord 21 Installation 21 Glass Frame Removal and Installation 22 Glass Frame Removal and Installation continued 23 Steps for Finalizing the Installation 24 Air Shutter Adjust...

Страница 4: ...ty hazard Direct questions about the type of fuel used to your dealer Check for a label on the flame adjust knob on the gas control valve this is the best place to check You may also check for a label...

Страница 5: ...t everyone in the house how to shut gas off to the appliance and at the gas main shutoff valve The gas main shutoff valve is usually next to the gas meter or propane tank and requires a wrench to shut...

Страница 6: ...00 500 to 1 500 Maximum BTU Input Per Hour 31 000 31 000 Heating capacity will vary with floor plan insulation and outside temperature Dimensions Electrical Specifications for optional blower Electric...

Страница 7: ...uch a standard is not applicable the Standard for Manufactured Home Installations ANSI NCSBCS A225 1 This appliance may be installed in Manufactured Housing only after the home is site located The hea...

Страница 8: ...re Burner 96900103 Media Logs Included w Burner Driftwood Log Set sku 94500548 Fyre Stone Stone Set sku 94700732 Log Set sku 94400991 Stone Set sku 94700729 Items Packed with the Face Face with attach...

Страница 9: ...allation This heater may be placed in a bedroom Please be aware of the large amount of heat this appliance produces when determining a location Fireplace Sizing 3 Piece Panel 1 Piece Panel Minimum Hei...

Страница 10: ...s etc The metal floor J may be removed to allow additional room for installation of the insert If the floor is removed the insert must be placed directly on the metal base of the metal fireplace The s...

Страница 11: ...al Requirements Route the power cord out of the access hole on the right side of the appliance Plug the power cord into a grounded 120 Volt outlet do not remove the grounding pin The electrical connec...

Страница 12: ...ces The maximum mantel depth is 12 305mm NOTE The combustible area above the facing must not protrude more than 3 4 20mm from the facing If it does it is considered a mantel and must meet the mantel r...

Страница 13: ...ackets with the screws included with the face see the instructions included with the face Mounting the Bedford Face Some Bedford Faces include old brackets that will not mount to the heater For these...

Страница 14: ...upply piping during any pressure testing of that system at test pressures in excess of 1 2 psig For pressures under 1 2 psig isolate the gas supply piping by closing the manual shutoff valve Leak test...

Страница 15: ...th of the chimney and terminate above the chimney top Be careful not to crimp or rupture the liner when bending it into chimney offsets When installed the vent must meet all of the vent manufacturer s...

Страница 16: ...with the restrictor in position number 1 Monitor the flame for 5 minutes before adjusting Move the restrictor a maximum two positions at a time by lifting the adjustment plate and moving it until the...

Страница 17: ...ermine if this installation is acceptable in your area This type of installation requires a minimum chimney cross section of 48 square inches 1 1 4 Center Line Inlet 3 Dia Exhaust 3 Dia Fireplace Open...

Страница 18: ...emove the vent connector and attach it to the flex vent see the instructions on the following page NOTE be careful of the anti seize on the connector it will stain clothing etc 3 Pull on the flex vent...

Страница 19: ...Attach the flex vent to the vent connector Slide the insert into place lining up these guides with the edges of the vent connector Push the vent connector rod in lift slightly and line it up so the t...

Страница 20: ...side surround panel and insert two screws from the inside to secure in place 5 16 Nutdriver Pre thread the holes on the surround panels with the screws included in the surround panel kit b a Run the...

Страница 21: ...Power Cord Because this panel fits flush against the fireplace facing the panel does not have a notch allowing the power cord to exit the fireplace We recommend using the insert wiring kit sku 9720031...

Страница 22: ...the right a Glass Frame Lift the glass frame up and pull it forward to remove NOTE You may need to lift the glass frame while re attaching b Re Attaching the Glass Frame a Hang the glass frame on the...

Страница 23: ...latch is turned 1 8 turn when disengaged from the unit Follow the directions below to re install the latch if it comes loose Glass Hold the latch at an angle and insert it into the slot on the glass f...

Страница 24: ...cover included in the owner s pack see illustration below The AA batteries act as a power backup in case the household AC power goes out and are required for operation Install the 9v battery included...

Страница 25: ...t position the flames should not contact the top of the firebox Check the flame on low position The flames should burn off of each burner hole If the heater does not work correctly contact your Travis...

Страница 26: ...so supplies low voltage for the fireplace controller By leaving it in the OFF position the fireplace will operate off the receiver batteries greatly diminishing battery life Figure 1 Synchronize the T...

Страница 27: ...om Condensation may appear on the glass each time you start the heater this is normal Blue Flames will occur on the heater when it first comes on After fifteen minutes the flames will turn a more real...

Страница 28: ...is controlled by the transmitter Figure 3 NOTE When the receiver switch is turned to ON or OFF the mode settings Accent Light Blower Flame Height Comfort Control will remain in the same state as befor...

Страница 29: ...burner If this is situation we recommend you switch to continuous pilot This will create a slight draft in the vent allowing for the burner to light quickly and draft correctly Excessive Condensation...

Страница 30: ...n for the Beep Each time you press a button on the transmitter that controls the fireplace a beep will come from the fireplace When you change thermostat target settings the fireplace will not beep NO...

Страница 31: ...MOSTAT While in standard thermostat setting the transmitter will turn the burner on and off to achieve the target temperature see Figure 8 below To adjust the target temperature press the up and down...

Страница 32: ...settings from OFF to HI for full on Figure 11 MANUAL MODE INSERTS SERIAL NUMBER 3401 144837 OR GREATER When in Manual Mode the blower will remain on even if the burner is turned off and the heater coo...

Страница 33: ...to OFF see the previous page Comfort Control rear burner The comfort control rear burner may be turned on and off using the up and down buttons when in Comfort Control Mode see Figure 13 The center di...

Страница 34: ...ation on page 36 In applications where the appliance is required to provide heat we recommend replacing the batteries before each heating season Child Proof Feature The child proof feature disables th...

Страница 35: ...ar a dull clicking sound This is the valve opening up and shutting down Blower Snap Disk This part can produce a clicking sound as it turns the blower on and off The appliance may creak with change of...

Страница 36: ...ntrol the comfort control and act as a power backup in case the household AC current goes out Control Panel Light Battery LED lights and a 9v battery are used to illuminate the control panel when the...

Страница 37: ...ng A small amount of soot along the bottom of the logs is normal If excessive sooting is found the heater will require adjustment Contact your dealer 4 Inspect the burner and remove any debris Make su...

Страница 38: ...ff for 5 seconds make sure standing pilot is off then turn back on Contact your dealer if this occurs Thermostat Does Not Work The receiver switch is turned to OFF or ON The thermostat is set too low...

Страница 39: ...nsed or qualified service person Contact your local Travis Industries Dealer for a Replacement Parts List CN4 CN3 PILOT SENSOR SPARK ROD DIGITAL FIREPLACE BURNER CONTROL CN2 GROUND VALVE COMMAND POWER...

Страница 40: ...e vent air intake system is disconnected for servicing or any other reason it must be resealed and or reinstalled WARNING Improper installation adjustment alteration service or maintenance can cause i...

Страница 41: ...lack of proper and regular maintenance damage incurred while the appliance is in transit alteration or act of God 8 This 7 Year warranty excludes damage caused by normal wear and tear such as paint d...

Страница 42: ...life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specif...

Страница 43: ...al Gas LP Propane Front Burner Orifice 50 DMS 56 DMS Rear Burner Orifice 47 DMS 56 DMS 4 Replace the manifold cover Place two orifice gaskets included with appliance on the front orifice see illustrat...

Страница 44: ...ORIENTED Secure using the screws included with the motor tighten to 25 Lb inches Leak test this area after installation to verify proper installation Re attach the wiring 8 Restore the appliance to t...

Страница 45: ...Index 45 Travis Industries 4120228 100 01285_000...

Страница 46: ...Requirements 10 Heating Specifications 6 Installation Options 6 Installation Warnings 7 Items Packed with the Face 8 Leveling Bolts 11 Location of Controls 27 Low Battery Indicator 34 LP Conversion In...

Отзывы: