Installation (for qualified installers only)
13
© Travis Industries
4120228
100-01285_000
Face Mounting Brackets -- Arched, Metropolitan, Artisan Vict. Lace
Faces
Some Arched, Artisan, Metropolitan, and Victorian Lace Faces include old brackets that will not
mount to the heater (see illustration below). For these faces, make sure to use the new mounting
brackets (either included with the heater or available through your dealer - SKU 250-00519).
WARNING
: When attaching the Victorian Lace Face,
do not over-tighten the screws
. Over-
tightening the screws may damage the face – simply tighten the screws until they contact the face.
NOTE: The face attaches to the brackets with the screws included with the face – see the instructions
included with the face.
Mounting the Bedford Face
Some Bedford Faces include old brackets that will
not mount to the heater. For these faces, make
sure to use the new DVS Insert EF II Face Upgrade
Kit (either included with the face or available
through your dealer - SKU 250-00029). The kit
lowers the face and surround panels 1-1/4”. This
means you must install this with a raised fireplace
or raise the insert 1-1/4” (32mm) above the hearth.
To do this you may extend the leveling bolts or
place bricks or other non-combustible under the
insert.
Old Arched,
Metropolitan, or
Artisan Bracket
New
Bracket
Old Victorian
Lace
Bracket
Install the face mounting brackets to
the heater with the included nuts.
NOTE: The brackets
install with this pair of
closely spaced
flanges at the top.
1-1/4”