Travis Industries DVL GSR2 NB Скачать руководство пользователя страница 6

6

 

Features and Specifications 

© Travis Industries 

4140813 

100-01294 

Features 

Works During Power Outages (battery backup system) 

Blower and Remote Control Included 

Standing or Intermittent (GreenSmart) Pilot 

Convenient Operating Controls 

- Variable-Rate 

Heat 

Output 

- Accent 

Light 

 

Installation Options 

 

Residential or Mobile Home 

 Fireplace 

Insert 

 

Masonry or Factory Built (Metal) Wood-
Burning Fireplace 

 

Natural Gas or Propane 

Heating Specifications 

 

Natural Gas 

Propane 

Approximate Heating Capacity (in square feet)* 

600 to 2,000 

600 to 2,000 

Maximum BTU Input Per Hour 

40,000 

40,000 

Heating capacity will vary with floor plan, insulation, and outside temperature. 

Dimensions 

 

Electrical Specifications (for optional blower) 

Electrical Rating ............................................................. 115 Volts, 1.5 Amps, 60 Hz (180 watt) 

Fuel 

This heater is shipped in natural gas (NG) configuration but may be converted to use propane (LP) 
using a conversion kit.  The sticker on top of the gas control valve will verify the correct fuel.  

20" (508mm) *

14-1/2" (369mm) *

1-1/4" (32mm) *

See "Surround 

Panels" for sizing

31-1/2" (801mm) *

23-3/4" (604mm) *

Front

avant

Right

droit

Rear

arrie're

Left

a' gauche

* See "Fireplace Requirements" for sizing 
details with 1-piece or 3-piece panels.

See "Surround 

Panels" for sizing

Содержание DVL GSR2 NB

Страница 1: ...BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be instal...

Страница 2: ...Insert has the same serial number as yours The serial number is attached to the appliance near the gas control valve This serial number will be needed in case you require service of any type Model DVL...

Страница 3: ...ontinued 23 Steps for Finalizing the Installation 24 Air Shutter Adjustment 25 Before You Begin 26 Remote Control Warnings 26 Remote Set Up 27 Verify the Switch is on REMOTE 27 Synchronize the Transmi...

Страница 4: ...in Manufactured Housing only after the home is site located All exhaust gases must be vented outside the structure of the living area Combustion air is drawn from outside the living area structure Th...

Страница 5: ...g and maintenance instructions that you will need at a later time Always follow the instructions in this manual Instruct everyone in the house how to shut gas off to the appliance and at the gas main...

Страница 6: ...600 to 2 000 600 to 2 000 Maximum BTU Input Per Hour 40 000 40 000 Heating capacity will vary with floor plan insulation and outside temperature Dimensions Electrical Specifications for optional blowe...

Страница 7: ...e LP All exhaust gases must be vented outside the structure of the living area Combustion air is drawn from outside the living area structure Notify your insurance company before hooking up this heate...

Страница 8: ...Kit Gas Line Equipment This Insert Requires a Burner Kit and Media logs stones This fireplace is shipped without a burner This allows the fireplace to be configured in unique designs See the table be...

Страница 9: ...aced in a bedroom Please be aware of the large amount of heat this appliance produces when determining a location Fireplace Sizing 3 Piece Panel 1 Piece Panel Minimum Height 23 3 4 604mm 24 7 8 632mm...

Страница 10: ...es etc The metal floor J may be removed to allow additional room for installation of the insert If the floor is removed the insert must be placed directly on the metal base of the metal fireplace The...

Страница 11: ...ment Electrical Requirements Route the power cord out of the access hole on the right side of the appliance Plug the power cord into a grounded 120 Volt outlet do not remove the grounding pin The elec...

Страница 12: ...top facing must extend 35 5 902mm above the base of the insert or to the bottom of the mantel whichever is less Mantel Clearances The maximum mantel depth is 12 305mm NOTE The combustible area above t...

Страница 13: ...ply piping during any pressure testing of that system at test pressures in excess of 1 2 psig For pressures under 1 2 psig isolate the gas supply piping by closing the manual shutoff valve Leak test a...

Страница 14: ...ate above the chimney top Be careful not to crimp or rupture the liner when bending it into chimney offsets When installed the vent must meet all of the vent manufacturer s requirements Use the follow...

Страница 15: ...reduce restrictor setting The restrictor is adjusted with the face removed Start with the restrictor in position number 1 Monitor the flame for 5 minutes before adjusting Move the restrictor a maximu...

Страница 16: ...this installation is acceptable in your area This type of installation requires a minimum chimney cross section of 48 square inches 2 Center Line Inlet 3 Dia Exhaust 4 Dia Fireplace Opening 1 1 2 4 1...

Страница 17: ...ove the vent connector and attach it to the flex vent see the instructions on the following page NOTE be careful of the anti seize on the connector it will stain clothing etc 3 Pull on the flex vent u...

Страница 18: ...ttach the flex vent to the vent connector Slide the insert into place lining up these guides with the edges of the vent connector Push the vent connector rod in lift slightly and line it up so the tab...

Страница 19: ...ews from the inside to secure in place 5 16 Nutdriver Pre thread the holes on the surround panels with the screws included in the surround panel kit b a Run the power cord to the right of the insert T...

Страница 20: ...00315 to route power to the insert Otherwise route the power cord behind the panel to the right side the panel or fireplace may be notched if required Installation 1 Attach the mounting brackets as sh...

Страница 21: ...Installation for qualified installers only 21 Travis Industries 4140813 100 01294 2 Attach the surround panel as shown below...

Страница 22: ...ke or slam the glass Open the four latches holding the glass frame in place start with the two below the glass follow the directions shown to the right a Glass Frame Lift the glass frame up and pull i...

Страница 23: ...tch is turned 1 8 turn when disengaged from the unit Follow the directions below to re install the latch if it comes loose Glass Hold the latch at an angle and insert it into the slot on the glass fra...

Страница 24: ...sure the accent light bulbs are in place and work correctly NOTE Take care to not touch the bulb with your fingers use a cloth or paper towel Rear Accent Light Firebox Ceiling Accent Light 4 Install t...

Страница 25: ...lame to its highest position the flames should not contact the top of the firebox Check the flame on low position The flames should burn off of each burner hole If the heater does not work correctly c...

Страница 26: ...tart in standing pilot mode If this occurs when the heater is in Remote Mode you will not be able to turn the heater off manually from the battery box If you need to replace dead batteries make sure t...

Страница 27: ...times 2 Press the ON button on the transmitter IFC will beep 3 times Figure 2 NOTE If power is cut off to the IFC for an extended period of time you may need to re synchronize the remote Clearing the...

Страница 28: ...e battery holder switch is turned to ON or OFF the mode settings Flame Height Comfort Control will remain in the same state as before the switch was moved i e the IFC remembers the last setting If you...

Страница 29: ...very cold conditions you may notice that the burner does not light quickly and the flames lift off the burner If this is situation we recommend you switch to continuous pilot This will create a slight...

Страница 30: ...tions see Figure 5 Figure 5 Listen for the Beep Each time you press a button on the transmitter that controls the fireplace a beep will come from the IFC When you change thermostat target settings the...

Страница 31: ...8 STANDARD THERMOSTAT While in standard thermostat setting the transmitter will turn the burner on and off to achieve the target temperature see Figure 9 below To adjust the target temperature press...

Страница 32: ...splay will display the 7 settings from OFF to HI for full on Figure 12 MANUAL MODE BLOWER OPERATION When in Manual Mode the blower will remain on even if the burner is turned off and the heater cools...

Страница 33: ...ned on and off using the up and down buttons when in Comfort Control Mode see Figure 14 The center display will display either ON or OFF Figure 14 Display Fahrenheit or Celsius With the system in the...

Страница 34: ...here the appliance is required to provide heat we recommend replacing the batteries before each heating season Battery Replacement Battery Installation Install four AA batteries into the battery holde...

Страница 35: ...normal during start up You may notice the smell is more acute if the appliance was left idle for a long period MAX F OFF Child Proof Indicator Gas Control Valve As the gas control valve is turned on...

Страница 36: ...ome etched into the surface Accent Light Replacement The accent light in your heater provides additional lighting The bulbs will burn out over time To replace follow the directions below Shut off gas...

Страница 37: ...this cavity to ensure the wiring is not pinched Loosen the two screws nearest the bulb to disengage the bulb from the holder Remove the bulb from the holder Replace the bulb making sure not to touch...

Страница 38: ...maged Check the firebox and area around the pilot to make sure there is no warping or damage If any problem is found discontinue use and contact your dealer for service 5 Replace the media Clean and r...

Страница 39: ...The battery box switch is turned to OFF or ON The thermostat is set too low Turn the battery box switch to REMOTE Check thermostat Blower Does Not Work The fireplace is not getting electricity The fir...

Страница 40: ...be done by a licensed or qualified service person Contact your local Travis Industries Dealer for a Replacement Parts List Orange Yellow System Jumper Purple Grey Pilot Sensor Spark Rod Comfort Contro...

Страница 41: ...nnected for servicing or any other reason it must be resealed and or reinstalled WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to...

Страница 42: ...f components lack of proper and regular maintenance damage incurred while the appliance is in transit alteration or act of God 8 This 7 Year warranty excludes damage caused by normal wear and tear suc...

Страница 43: ...personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted ap...

Страница 44: ...the LP propane orifices ORIFICE SIZE ID Natural Gas LP Propane Front Burner Orifice 49 DMS 57 DMS Rear Burner Orifice 43 DMS 53 DMS 5 Install the LP manifold cover included in the owner s pack see bel...

Страница 45: ...tion sheet included with it make sure to follow all the directions Disconnect the wiring from the stepper motor Remove the stock stepper motor and replace with the LP version MAKE SURE IT IS CORRECTLY...

Страница 46: ...n Options 6 Installation Warnings 7 Intermittent Continuous Pilot 29 Items Packed with the Face 7 Leveling Bolts 11 Location of Controls 28 Low Battery Indicator 34 Lower Accent Light 36 LP Conversion...

Отзывы: