Installation (for authorized personnel only)
© Travis Industries
4040808
100-01201_000
Top Convection Deflector
Install the top convection deflector as shown to the
right.
The deflector is shipped on top of the insert. The
screws are shipped inside the owner's pack.
Fireplace Requirements
•
Insert must be placed within a code-conforming masonry fireplace. Repair any fireplace damage
prior to installation.
•
Because the insert uses a circulation blower, clean the fireplace, smoke shelf, and chimney prior to
installation.
•
This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.
The DVL inserts 368mm into the
fireplace.
Min. 800mm
- additional space may be required for gas line installation
For tight fits (under 711mm), you may remove the manifold. See the section
"Removing the Manifold"
See "Leveling Bolts" for details
on leveling the heater.
Min. 603mm
The gas line and shutoff
valve should be installed
prior to insert placement.
Attach the "This fireplace has been altered..." plate
to the fireplace (use two screws or other suitable
method). You may wish to place it in a location
where it will be covered by the surround panels.