16
Stove Installation
(for qualified installers only)
Travis Industries
93508133
4 020509
H e a r t h
S t o v e
D i r e c t
Co n n ectio n
N O T E :
Direct
connections
require installation
of an airtight, non-
combustible
block-off plate or
damper adapter.
AAA
AAA
AAA
AAA
AAA
AAA
AAA
A
A
A
A
A
Block-off plate or
damper adapter
Remove damper
or wire it open
Airtight
Insulated
Clean-Out
Stainless steel
chimney connector
must Extend 1' past
the block-off plate or
to the flue liner
NOTE: The chimney must have a clay
tile liner. If it does not, the installation
must use a positive connection (full
reline). The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes (UBC,
etc.). Damage must be repaired prior
to installation. The chimney must be
15' to 33' tall.
Clay
Liner
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
Combustible Mantle
Min. 18"
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Max. 8”
Interior or
E x t e r i o r
M a s o n r y
C h i m n e y
N O T E :
This type of
installation
requires a UBC
approved
masonry
connector or a
factory built (U.L.
Listed) wall
thimble.
Make sure the
clean-out seals in
place.
Clay Liner
See the section "Stove
Placement Requirements" for
minimum clearances required.
Min. 18"
clearance
to ceiling
This type of
installation requires
a UBC approved
masonry connector
or a factory built
(U.L. Listed) wall
thimble.
Chimney connector sections
NOTE: The chimney must have a
clay tile liner. If it does not, the
installation must use a positive
connection (full reline). The
entire fireplace and chimney must
be clean, undamaged, and meet
all local building codes (UBC,
etc.). Damage must be repaired
prior to installation. The chimney
must be 15' to 33' tall.
See the section
"Floor Protection
Requirements"