Maintenance
33
© Travis Industries
4012412
100-01270_000
Monthly Maintenance (or Every 20 Bags of Pellets) - Clean Vertical Exhaust Ducts
1. Remove the fire cover (see the section “Cleaning the Fire Platform” on page 30).
2. Remove the left and right vertical exhaust duct covers (see the photos below).
3. Use the included bottle brush to remove accumulated flyash from the vertical exhaust channels (both
sides). You may need to bend the bottle brush to allow it to access this area. Sweep the flyash out of
the exhaust channels and into the ashpan.
4. If you have a suitable ash vacuum, remove accumulated flyash from the horizontal exhaust channels
along the perimeter of the firebox and leading to the exhaust blower.
Monthly Maintenance (or Every 20 Bags of Pellets) - Clean the Glass
Open the doors and clean the glass with a non-abrasive glass cleaner and rag.