Remote Thermostat
Operating Instructions
Page 2 of 4
9/28/05
Travis Industries, Inc.
OPERATING INSTRUCTIONS
NOTE :
This kit must be installed by a qualified technician to work correctly
NOTE :
On gas stoves the pilot flame must be lit, the gas control valve turned to "ON", and the on/off switch
turned to "OFF" for the remote to work correctly.
NOTE :
The remote must be calibrated before it will work (see the instructions on the previous page). If the
remote fails to work, try unplugging the remote receiver, plugging it back in, then re-calibrate the remote.
MODES OF OPERATION:
Manual Mode
Use manual mode to turn the heater on
and off directly.
OFF
ROOM TEMP
°F
°F
SET TEMP
TIMER
MIN
TO TURN ON AND OFF:
Use this key to toggle the
heater on and off. The
display will indicate the
status.
NOTE:
-- If the room exceeds 90°,
the heater will shut off.
-- If left on, the heater will
shut off after 6 hours.
TIMER
CLOCK
MANUAL
ON/
OFF
ON/
OFF
AU
TO
Auto Mode
Auto mode works like a
thermostat, turning the heater on
and off to meet the desired
temperature.
Auto
ROOM TEMP
°F
°F
SET TEMP
MIN
THERMOSTAT MODE:
Use this key to toggle the
thermostat mode. The
display will indicate
“AUTO” when in
thermostat mode.
TO ADJUST TARGET
TEMPERATURE:
Use the arrow keys to adjust the target
temperature to the desired level.
The heater will turn on and off to keep
the room temperature near the target
temperature.
IMPORTANT NOTES:
-- The thermostat has a delay to prevent
the heater from turning on and off
repeatedly. As a result, the target
temperature may be slightly higher (2°
or 3°) than the room temperature yet
the heater does not turn on – do not
adjust the target temperature – the
heater will turn on in a few minutes.
-- The thermostat is not intended for un-
attended use. If the thermostat calls for
heat for 6 hours continuously, it will shut
off and not turn on until reset.
HINT:
If your heater turns on
and off frequently, adjust
the flame height down
slightly for a more
consistent heat output.
TIMER
CLOCK
MANUAL
ON/
OFF
ON/
OFF
AU
TO