![Travis Industries 864 TRV GS2 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/travis-industries/864-trv-gs2/864-trv-gs2_installation-manual_1154067009.webp)
Installation
(for qualified installers only)
9
Travis Industries
4121102
100-01301
Top Vent or Rear Vent Configuration
This appliance is shipped in the rear vent configuration. To change to the top vent configuration, follow
the directions below.
NOTE
: the vent configuration affects several aspects of installation (framing, maximum vent rise,
maximum vent run). Make sure the vent configuration is correct prior to installation. You may wish to
configure the diffuser when changing the vent configuration.
Converting
the Fireplace
to Top Vent
Configuration
Remove and discard all of
the insulation found near
the flue assembly (make
sure to remove every
piece).
Remove the 4 screws
securing the intake
cover plate. Remove
it and place it aside.
Remove the 4 screws securing
the cover plate. Remove it and
place it aside.
Remove the 4 screws
securing the cover
plate (with hole).
This part may be
discarded.
Top of Fireplace
Back of Fireplace