Blower Components
5 - 3
Travis Industries
Gas T-Shoot Guide
19203
Lopi Spirit (B-Vent & DV) Blower Removal
Warning
Make sure the power cord is disconnected prior to conducting service.
Warning
Shut off gas to the heater - you may need to disconnect the gas line
depending upon the heater location and the type of gas connection.
1
Remove the two screws on the cover plate
around the gas inlet. Unscrew the nine
screws holding the rear panel in place.
5/16" Nutdriver
Cover Plate
2
Swing the rear panel to the left and
disconnect the molex connector leading
from the power cord.
Remove the Molex Connection
3
Remove the nuts holding the left side
panel to the baseplate.
Remove these nuts (left side only)
3/8" Wrench
4
Remove the nuts holding the left side
panel to the convection top.
Remove these nuts (left side only)
3/8" Wrench
5
Remove the left side panel by lifting up on
the top convection panel and lifting the
panel free of the base.
6
With the left rear of the heater exposed,
the blower assembly can be accessed.
Follow the directions on page 5-5 (A20
Blower Assembly Removal & Disassembly)
to remove the blower from the heater.