VIII. e - INCOMPLETE THAWING:

In  operation,  incomplete  thawing  (i.e.  bags  of  product  in 

which not every piece was completely thawed) has been 

found to usually be the result of those pkgs. respective pan 

level having had restricted airflow due to overloading (from 

stacked pkgs. or irregular shaped packages that blocks air 

from getting to the pkgs. closest to the cabinet interior side 

wall or rear). Allowing for proper air-flow around each pkgs. of 

frozen product should eliminate this situation from occurring.

VIII. f - EQUIPMENT ISSUES:

If improper loading has been eliminated as a possible cause 

for  extended  thaw  cycle  times,  there  are  several  system 

checks which can be done to diagnose the Traulsen Even-

Thaw unit. 

First, the amp draw should be checked early in the thaw cycle. 

This is a 1300 watt heater, 115 vac, is about 11.3 amps. Add 

4 blowers at 1.1 amps and a few amps for the controls and 

the total amp draw should be approximately 16 to 16.5 amps. 

If your amp reading is different, call Traulsen technical sup

-

port to help diagnose the problem.

VIII. g - OTHER CAUSES OF EXTENDED THAW TIMES:

Some frozen products are often stored in large, irregularly 

shaped packages. If used, these should always be located 

along the outside wall with the largest packages being placed 

closest to, but not directly against, the wall. It is IMPERA

-

TIVE that such large packages not be placed up against the 

center mullion air ducts. This could result in blocked airflow.

REDUCED AIR MOVEMENT EQUATES TO LONGER

THAWING TIMES.

Care should also be taken to avoid pushing other pkgs. of 

frozen product up against the mullion sheet metalducts. 

Airflow could be blocked resulting in a similarextended thaw 

time situation. Another scenario to avoid is for packages to 

be placed inadvertently up against the outside walls. They 

will also block air flow down the sides of the unit. This is 

especially an issue with the right side wall because when 

the unit returns to normal refrigerated operation mode, the 

cold air flows from the upper right ceiling evaporator outlet, 

down the wall, and then mixes into the cabinet, distributed 

by all the mullion blowers. If the right wall is blocked, and 

especially if blocked near the top right of the cabinet, the cold 

evaporator exit air can be short circuited on to the top two or 

three upper right hand levels and be routed right back to the 

return evaporator inlet duct. Therefore, those upper shelves 

could get very cold and perhaps a substantial amount of 

product on the right side could become very cold and pos-

sibly even refreeze (as the evaporator outlet air temperature 

is 20 degrees F).

VIII. EXPECTED THAW PERFORMANCE/OPERATIONAL TROUBLESHOOTING 

(continued)

Содержание RET132EUT

Страница 1: ... refer to the model and serial number found on the name tag affixed to the unit Should you need service however call us on our toll free number 800 825 8220 between 7 30 am and 4 30 pm CST Monday thru Friday It is our pleasure to help and assist you in every possible way OWNER S MANUAL Instructions for the installation operation and maintenance of all Traulsen Reach In Even Thaw Refrigerator Model...

Страница 2: ...ESIGN PRESSURE HIGH LOW FORT WORTH TX 370 60294 00 REV A I THE SERIAL TAG Page 1 II RECEIPT INSPECTION Page 2 III INSTALLATION a Location Page 2 b Packaging Page 2 c Installing Legs or Casters Page 2 d Tray Slides Page 3 e Cord Plug Page 3 f Power Supply Page 3 g Wiring Diagram Page 3 h Clearance Page 3 IV OPERATION a Even Thaw Overview Page 3 b Expected Performance Page 3 c Even Thaw Operation Pa...

Страница 3: ... service remove and discard the covering from all surfaces To remove the wooden pallet first if at all possible we suggest that the cabinet remain bolted to the pallet during all transportation to the point of final installa tion The bolts can then be removed with a 3 4 socket wrench Avoid laying the unit on its front side or back for removal of the pallet NOTE DO NOT LAY THE UNIT ON ITS SIDE DURI...

Страница 4: ... EVEN THAW OVERVIEW The Even Thaw refrigerator was specially designed to thaw frozen food product under safe temperature controlled condi tions It is not intended as a storage refrigerator NOTE USING THIS REFRIGERATOR FOR STORAGE OF UNCOVERED PRODUCT IS NOT RECOMMENDED IV b EXPECTED PERFORMANCE The Traulsen Even Thaw refrigerator is designed to thaw a full load of frozen food product see BATCH LOA...

Страница 5: ...vice De partment at 800 825 8220 V a CLEANING THE CONDENSER The most important thing you can do to insure a long reli able service life for your Traulsen is to regularly clean the condenser coil The condensing unit requires regularly scheduled cleaning to keep the finned condenser clean of lint and dust accum mulation Keeping the condenser clean allows the cabinet to operate more efficiently and u...

Страница 6: ... form should appear Complete the required information and hit the SUBMIT button when finished V CARE MAINTENANCE continued V c REPLACING THE GASKETS To remove the gasket to be replaced grasp it firm ly by one corner and pull it out Before attempting to in stall a new gasket both the unit and the gasket itself must be at room temperature Insert the four corners first by using a rubber mallet or ham...

Страница 7: ...f product for example approximately 672 lbs of chicken Use of aluminum pans is highly recommended Product should be placed on pans in one layer only to allow for proper airflow With a full load thaw time will be between 22 24 hours Overloading and or double wrapping product will extend thaw times VIII a INTRODUCTION Even thaw performance is a function of many factors espe cially those involving pr...

Страница 8: ...the largest packages being placed closest to but not directly against the wall It is IMPERA TIVE that such large packages not be placed up against the center mullion air ducts This could result in blocked airflow REDUCED AIR MOVEMENT EQUATES TO LONGER THAWING TIMES Care should also be taken to avoid pushing other pkgs of frozen product up against the mullion sheet metalducts Airflow could be block...

Страница 9: ...r continuously b Dirty condenser or filter Clean properly c Evaporator coil iced Needs to defrost d Shortage of refrigerant call service 3 Food compartment is too warm a Check door s and gasket s for proper seal 4 Condensation on the exterior surface a Check door alignment and gaskets for proper seal 5 Compressor hums but does not start a Call for service 6 Excessively long product thaw times a Ca...

Страница 10: ...EEN 337 60406 02 ALL MODELS COIL SENSOR BLUE 337 60407 01 ALL MODELS LIQUID LINE SENSOR YELLOW 337 60346 00 RE132E RE232N OFF ON POWER SWITCH 337 60346 01 RE232E OFF ON POWER SWITCH 341 60062 05 RE132E RE232N AIR FILTER 341 60062 06 RE232E AIR FILTER 325 60013 10 RE132E RE232N MULLION BLOWER 325 60013 11 RE232E MULLION BLOWER 325 60071 01 RE132E RE232N EVAPORATOR BLOWER 325 60013 11 RE232E EVAPORA...

Страница 11: ... 10 XI WIRING DIAGRAM ALL ONE SECTION MODELS ONLY ...

Страница 12: ... 11 XI WIRING DIAGRAM MODELS RET232NUT FHS RET232NUT HHS ONLY ...

Страница 13: ...XI WIRING DIAGRAM MODELS RET232EUT FHS RET232EUT HHS ONLY 12 ...

Страница 14: ...y claim this warranty statement and forfeit payment for those repairs effected This warranty does not apply to damage resulting from fire water burglary accident abuse misuse transit acts of God terrorism attempted repairs im proper installation by unauthorized persons and does not apply to food loss and will not apply if said equipment is located outside The United States G SERIES MICROPROCESSOR ...

Страница 15: ...Notes ...

Страница 16: ...Blue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration 2012 Traulsen All Rights Reserved ...

Отзывы: