background image

TABLE OF CONTENTS

The  serial  tag  is  a  permanently  affixed  sticker  on 

which is recorded vital electrical and refrigeration 

data about your Traulsen product, as well as the 

model and serial number.  This tag is located in 

the upper right interior compartment on all reach-

in/pass-thru and roll-in/roll-thru refrigerator, freezer 

and dual-temp models.  For hot food models, this tag 

is located on the top of the unit behind the louvers to 

protect it from the heat.

I. THE SERIAL TAG

-1-

READING THE SERIAL TAG

 Serial = The permanent ID# of your Traulsen

 Model = The model # of your Traulsen

 Volts = Voltage

 Hz = Cycle 

 PH = Phase

 Total Current = Maximum amp draw

 Minimum Circuit = Minimum circuit ampacity

 Lights = Light wattage

 Heaters = Heater amperage (Hot Food units only)

 Refrigerant = Refrigerant type used

 Design Pressure = High & low side operating

  pressures and refrigerant charge

 Agency Labels = Designates agency listings

 

SERIAL  

 

MODEL

VOLTS 

 

 

 

  Hz    

       PH 

TOTAL CURRENT 

 

AMPS

MINIMUM CIRCUIT 

 

AMPS

MAXIMUM OVERCURRENT PROTECTION 

 

AMPS

LIGHTS   WATTS

HEATERS 

  AMPS

REFRIGERANT   TYPE 

 OZ

DESIGN 

PRESSURE 

  HIGH 

 LOW

REFRIGERANT   TYPE 

 OZ

DESIGN 

PRESSURE 

  HIGH 

 LOW

FORT WORTH, TX. 

370-60294-00 REV (A)

I. 

THE SERIAL TAG 

 

 

 

 

Page 1

II. 

RECEIPT INSPECTION 

 

 

 

Page 2

III. 

INSTALLATION

 

a-Location  

 

 

 

Page 2

 

b-Packaging  

 

 

 

Page 2

 

c-Installing Legs or Casters  

 

Page 2

 

d-Tray Slides  

 

 

 

Page 3

 

e-Cord & Plug    

 

 

Page 3

 

f-Power Supply    

 

 

Page 3

 

g-Wiring Diagram  

 

 

Page 3

 

h-Clearance  

 

 

 

Page 3

IV. 

OPERATION

 

a-Even-Thaw Overview    

 

Page 3

 

b-Expected Performance    

 

Page 3

 

c-Even-Thaw Operation    

 

Page 3

 

d-Batch Loading    

 

 

Page 4

 

e-Process Loading  

 

 

Page 4

 

f-Interior Arrangements    

 

Page 4

 

g-Adjusting The Temperature Scale   

Page 4

 

h-Operator Controls, Blower Switch   

Page 4

 

i-Call Service Light  

 

 

Page 4

V. 

CARE & MAINTENANCE

 

a-Cleaning The Condenser  

 

Page 4

 

b-Hinge Replacement  

 

 

Page 4

 

c-Replacing The Gaskets    

 

Page 5

 

d-Cleaning The Exterior    

 

Page 5

 

e-Cleaning The Interior    

 

Page 5

VI. 

OTHER

 

a-Service Information  

 

 

Page 5

 

b-Spare Parts    

 

 

Page 5

 

c-Warranty Registration    

 

Page 5

VII. 

GEN’L USE, OPERATION & SERVICE 

   

Page 6

VIII. 

EXPECTED THAW PERFORMANCE/ 

       OPERATIONAL TROUBLESHOOTING

 

a-Introduction    

 

 

Page 6

 

b-Test Parameters  

 

 

Page 6

 

c-Test Results    

 

 

Page 6

 

d-Results as a Function of Product Mix  

Page 6

 

e-Incomplete Thawing  

 

 

Page 7

 

f-Equipment Issues  

 

 

Page 7

 

g-Causes Of Extended Thaw Times  

Page 7

IX. 

TROUBLE SHOOTING GUIDE

   

 

Page 8

X. 

SPARE PARTS LIST

    

                          Page 9

XI. 

WIRING DIAGRAMS    

 

           Page 10-12

XII. 

WARRANTY INFORMATION 

   

 

Page 13

Содержание RET132EUT

Страница 1: ... refer to the model and serial number found on the name tag affixed to the unit Should you need service however call us on our toll free number 800 825 8220 between 7 30 am and 4 30 pm CST Monday thru Friday It is our pleasure to help and assist you in every possible way OWNER S MANUAL Instructions for the installation operation and maintenance of all Traulsen Reach In Even Thaw Refrigerator Model...

Страница 2: ...ESIGN PRESSURE HIGH LOW FORT WORTH TX 370 60294 00 REV A I THE SERIAL TAG Page 1 II RECEIPT INSPECTION Page 2 III INSTALLATION a Location Page 2 b Packaging Page 2 c Installing Legs or Casters Page 2 d Tray Slides Page 3 e Cord Plug Page 3 f Power Supply Page 3 g Wiring Diagram Page 3 h Clearance Page 3 IV OPERATION a Even Thaw Overview Page 3 b Expected Performance Page 3 c Even Thaw Operation Pa...

Страница 3: ... service remove and discard the covering from all surfaces To remove the wooden pallet first if at all possible we suggest that the cabinet remain bolted to the pallet during all transportation to the point of final installa tion The bolts can then be removed with a 3 4 socket wrench Avoid laying the unit on its front side or back for removal of the pallet NOTE DO NOT LAY THE UNIT ON ITS SIDE DURI...

Страница 4: ... EVEN THAW OVERVIEW The Even Thaw refrigerator was specially designed to thaw frozen food product under safe temperature controlled condi tions It is not intended as a storage refrigerator NOTE USING THIS REFRIGERATOR FOR STORAGE OF UNCOVERED PRODUCT IS NOT RECOMMENDED IV b EXPECTED PERFORMANCE The Traulsen Even Thaw refrigerator is designed to thaw a full load of frozen food product see BATCH LOA...

Страница 5: ...vice De partment at 800 825 8220 V a CLEANING THE CONDENSER The most important thing you can do to insure a long reli able service life for your Traulsen is to regularly clean the condenser coil The condensing unit requires regularly scheduled cleaning to keep the finned condenser clean of lint and dust accum mulation Keeping the condenser clean allows the cabinet to operate more efficiently and u...

Страница 6: ... form should appear Complete the required information and hit the SUBMIT button when finished V CARE MAINTENANCE continued V c REPLACING THE GASKETS To remove the gasket to be replaced grasp it firm ly by one corner and pull it out Before attempting to in stall a new gasket both the unit and the gasket itself must be at room temperature Insert the four corners first by using a rubber mallet or ham...

Страница 7: ...f product for example approximately 672 lbs of chicken Use of aluminum pans is highly recommended Product should be placed on pans in one layer only to allow for proper airflow With a full load thaw time will be between 22 24 hours Overloading and or double wrapping product will extend thaw times VIII a INTRODUCTION Even thaw performance is a function of many factors espe cially those involving pr...

Страница 8: ...the largest packages being placed closest to but not directly against the wall It is IMPERA TIVE that such large packages not be placed up against the center mullion air ducts This could result in blocked airflow REDUCED AIR MOVEMENT EQUATES TO LONGER THAWING TIMES Care should also be taken to avoid pushing other pkgs of frozen product up against the mullion sheet metalducts Airflow could be block...

Страница 9: ...r continuously b Dirty condenser or filter Clean properly c Evaporator coil iced Needs to defrost d Shortage of refrigerant call service 3 Food compartment is too warm a Check door s and gasket s for proper seal 4 Condensation on the exterior surface a Check door alignment and gaskets for proper seal 5 Compressor hums but does not start a Call for service 6 Excessively long product thaw times a Ca...

Страница 10: ...EEN 337 60406 02 ALL MODELS COIL SENSOR BLUE 337 60407 01 ALL MODELS LIQUID LINE SENSOR YELLOW 337 60346 00 RE132E RE232N OFF ON POWER SWITCH 337 60346 01 RE232E OFF ON POWER SWITCH 341 60062 05 RE132E RE232N AIR FILTER 341 60062 06 RE232E AIR FILTER 325 60013 10 RE132E RE232N MULLION BLOWER 325 60013 11 RE232E MULLION BLOWER 325 60071 01 RE132E RE232N EVAPORATOR BLOWER 325 60013 11 RE232E EVAPORA...

Страница 11: ... 10 XI WIRING DIAGRAM ALL ONE SECTION MODELS ONLY ...

Страница 12: ... 11 XI WIRING DIAGRAM MODELS RET232NUT FHS RET232NUT HHS ONLY ...

Страница 13: ...XI WIRING DIAGRAM MODELS RET232EUT FHS RET232EUT HHS ONLY 12 ...

Страница 14: ...y claim this warranty statement and forfeit payment for those repairs effected This warranty does not apply to damage resulting from fire water burglary accident abuse misuse transit acts of God terrorism attempted repairs im proper installation by unauthorized persons and does not apply to food loss and will not apply if said equipment is located outside The United States G SERIES MICROPROCESSOR ...

Страница 15: ...Notes ...

Страница 16: ...Blue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration 2012 Traulsen All Rights Reserved ...

Отзывы: