LS802-GS standard User Manual

Size

100 x 140 mm

Material (recommened): 80g/m²  (80g

书纸

)

Color: black

Customizable : 

Update your company contact information on back cover

and Page 21

Transtek Logo → Customized Logo

Please read the user manual carefully and thoroughtly so as to ensure the 
safe usage of this product, keep the manual well for further reference in 
case you have problems.

version:1.0

User Manual

Blood Pressure Monitor

LS802-GS

Guangdong Transtek Medical Electronics Co., Ltd.

Zone A, No.105, Dongli Road, Torch Development 
District, Zhongshan, 528437, Guangdong, China  

 

Содержание LS802-GS

Страница 1: ...Logo Customized Logo Please read the user manual carefully and thoroughtly so as to ensure the safe usage of this product keep the manual well for further reference in case you have problems version 1...

Страница 2: ...INFORMATION FOR USER 14 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 16 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Irregular heartbe...

Страница 3: ...ed electrical devices such as cardiac pacemakers defibrillators Contraindications This product uses the Oscillometric Measuring method to detect blood pressure Before every measurement the unit establ...

Страница 4: ...ition and storage state The typical service life is 10000 times Dispose of accessories detachable parts and the device according to the local guidelines This device is intended for indoor home use Thi...

Страница 5: ...rs when decteted during a measurement Refer to page 17 for more information Signal indica on Indicates the signal situation in the communication process Date Time display 1 2 3 4 5 6 7 9 Data transmis...

Страница 6: ...er to depart from the using utility power when you finish the measurement 6V 1A Do not use new and used batteries together Do not use different types of batteries together Do not dispose the batteries...

Страница 7: ...ft arm use your right arm Roll or push up your sleeve to expose the skin Make sure your sleeve is not too tight 2 3 5 6 Sit upright in a comfortable chair with your back against the backrest of the ch...

Страница 8: ...n is achieved Tip You can press the START STOP button to stop the measurement any time 1 When the monitor is off press the START STOP button to turn on and then it will complete the whole measurement...

Страница 9: ...e temperature environment Do not attempt to clean the reusable cuff with water and never immerse the cuff in water Tips for Measurement Within 1 hour after dinner or drinking Within 20 minutes after t...

Страница 10: ...P range Please contact a physician if your measuring result falls out of the range Please note that only a physician can tell whether your blood pressure value has reached a dangerous point Irregular...

Страница 11: ...Install the batteries or plug in the adapter properly Replace with new batteries Batteries are installed incorrectly or Adapter is not plugged in properly Lo shows The battery is too low E 1 shows E 3...

Страница 12: ...s equipment is allowed Display mode Measurement mode Oscillographic testing mode Measurement range Measurement perimeter of the upper arm Weight External dimensions Mode of operation Continuous operat...

Страница 13: ...ions flicker emissions IEC 61000 3 3 Emissions test FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause ha...

Страница 14: ...d manufacturer s declaration electromagnetic Immunity Immunity Test 8 kV contact 2 kV 4 kV 8 kV 15 kV air 8 kV contact 2 kV 4 kV 8 kV 15 kV air 1 kV 2 kV 100 kHz repetition frequency For AC power port...