background image

CUFF

 AIR PIPE

AIR CONNECTOR PLUG

LCD DISPLAY

DC POWER SOCKET

User 1

Guest

User 2

BATTERY COMPARTMENT

Monitor Components

LCD Display Signal

5

4

List

1.Blood Pressure Monitor

  (LS802-E)

4.User manual

3. 4*AA alkaline batteries

2.Cuff 

(Type BF applied part) 

SYMBOL DESCRIPTION

Systolic blood pressure High pressure result

Diastolic blood pressure Low pressure result

EXPLANATION

Pulse

Pulse/minute

User 1

Provide measurement for user 1, and 

then save the measure data

Guest

Provide measurement for guests,

but not save the measurement data.

User 2

Provide measurement for user 2, and 

then save the measure data

Data storage

To remind the users that the measurement 

data don’t upload to bridge in time

Wireless transmitter

The blood monitor and Bridge in communication

Network connection

The bridge not connect the network

Shocking remainding

Shocking will result in inaccurate

Low battery

Batteries are low and need to be replaced

Measurement Unit of the blood pressure

Unit

date (hour:minute)

Currently time

Deflating

CUFF air is exhausting of deflating

Component list of 

pressure measuring system

1 Cuff 

2 Air pipe

3 PCBA

4 Pump

5 Valve

Arrhythmia

Irregular heartbeat

Heartbeat

Heartbeat detection during the measurement

INTRODUCTION

INTRODUCTION

(22~32cm or 22cm~42cm)

5. AC Adaptor 

(UE08WCP-060100SPA only!)

Содержание LS802-E

Страница 1: ...u very much for selecting TRANSTEK Blood Pressure Monitor LS802 E please keep well this manual in order to reference in future Arm Type Version 1 0 FCC ID OU9LS802 E02 GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO LTD Zone A 5 F Investment Building No 12 Huizhan East Rd Torch Development District Zhongshan Guangdong 528437 China ...

Страница 2: ...SER 10 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 12 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Why my blood pressure is varies even in one day Why the blood pressure I get from the hospital is different from home If the result is the same if measuring on the right arm TROUBLESHOOTING 14 SPECIFICATIONS 15 AUTHORIZED COMPONENTS 1...

Страница 3: ...e START STOP button to stop inflation The equipment is not AP APG equipment and not suitable for use in the presence of a flammable anesthetic mixture with air of with oxygen or nitrous oxide The operator shall not touch output of batteries adapter and the patient simultaneously To avoid measurement errors please avoid the condition of strong electromagnetic field radiated interference signal or e...

Страница 4: ...measurement for user 2 and then save the measure data Data storage To remind the users that the measurement data don t upload to bridge in time Wireless transmitter The blood monitor and Bridge in communication Network connection The bridge not connect the network Shocking remainding Shocking will result in inaccurate Low battery Batteries are low and need to be replaced Measurement Unit of the bl...

Страница 5: ...ws your blood circulation to recover For a meaningful comparison try to measure under similar conditions For example take daily measurements at approximately the same time on the same arm or as directed by a physician Tie the Cuff 1 Tie the cuff on your upper arm the position the tube off center toward the inner side of arm in line with the little finger 2 The cuff should be sung but not too tight...

Страница 6: ...ssful activation synchronization the equipment will display and transmit the measuring results after each measurement Activation synchroniz ation is proceeding The measureme nt data is uploading The data has been uploaded successfully CAUTION Interference may occur in the vicinity of equipment marked with the following symbol And LS802 E may interfering vicinity electrical equipment Sensitive peop...

Страница 7: ... it with a dry cloth in case Avoid the dusty and unstable temperature environment Avoid washing the cuff 11 10 Tips for measurement In a very cold environment Immediate measurement after tea coffee smoking When talking or moving your fingers When you want to discharge urine It can cause incorrectness if the measurement are taken in the following circumstances Within 20 minutes after taking a bath ...

Страница 8: ...LOOD PRESSURE If the result is the same if measuring on the right arm ABOUT BLOOD PRESSURE Irregular Heartbeat Detector This Blood Pressure Monitor is equipped with an intelligent function of Irregular Heartbeat IHB Detector During each measurement this equipment records the heartbeat intervals and works out the standard deviation If the calculated value is larger than or equal to 15 this equipmen...

Страница 9: ...th new batteries Batteries are inserted incorrectly Display is dim or show Batteries are low E 1 shows RF communication failed Check the database is power on or not Or synchronize the data operation E 3 shows E10 or E11 shows E20 shows Exxx shows on the display A calibration error occurred Retake the measurement If the problem persists contact the retailer or our customer service department for fu...

Страница 10: ...This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harm...

Страница 11: ...cle processes ISO EN 14971 2012 Medical devices Application of risk management to medical devices ISO EN 15223 1 2012 Medical devices Symbols to be used with medical device labels labelling and information to be supplied General requirements EN 1041 2008 Medical equipment manufacturers to provide information IEC 60601 1 2005 A1 2012 Medical electrical equipment Part 1 General requirements for basi...

Отзывы: