TRANSTEK LS208-B6 Скачать руководство пользователя страница 5

7

6

Initial Start-Up

Transtek Body Fat Analyzer LS208-B6 applies BIA (Bio-impedance Analysis) 

technology. A small amount of weak current flows through the human body so as to detect 

the bio-impedance and estimate body fat. The electrical current is small and may not be felt. 

This BIA technology is cheap, safe, non-invasive, toxic-free and harmless. It also 

possesses the characteristics of simple operation and abundant information. 

The current mentioned above is less than 0.5mA. However, please be aware that anyone 

with an wearable or implantable medical electronic instrument, such as a pacemaker, must 

avoid using this device.

The intended use of this device is for healthy children 10-17 years old and healthy adults. 

General Instructions

Insert the Batteries

Open the battery door in the back of the scale.

Insert the batteries (4 x 1.5V AAA) into the battery 

compartment according to the polarity indications 

marked inside the compartment.

* The digits “8888” will be shown on the LED.

Close the battery door and wait until the digits 

“0.0” are shown on the LED.

If SUCCEED, symbol         will be shown on the LED.

If FAIL, symbol “E1” will be shown on the LED.

Install App and Pair-Up

With the advanced Bluetooth 4.0 technology applied, the mobile or portable equipments, 

which are equipped with Bluetooth function in line with BLE Technical Specifications as 

well as BLP Protocol established by global organization Bluetooth SIG, are capable to 

receive your personal health data.

Just simply install the specially-designed app and pair up your scale with 

your mobile or portable equipments. Then you may enjoy the comprehensive health 

solution provided by Transtek.

Turn on Bluetooth and App. Make sure both are ON when pair-up is proceeding. 

Press and hold “UNIT” button in the back of the scale to start pair-up. 

Symbol         and symbol         will be shown on the 

LED alternatively, indicating pair-up is proceeding.

Initial Start-Up

CAUTION

When the symbol “Lo” appears, the device will power off. Then you shall replace with a new set of 

batteries. Please replace all four batteries at the same time. Do NOT mix the old batteries with the new 

one. 

Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage. 

Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries 

and scrapped device.

If you do not intend to use this unit for a prolonged period of time, it is advisable to remove the batteries

before storing.

Battery Life: Approx. 200 days

(Battery capacity: 452 mAH. If measured three times per day, each measurement takes about 20s. 

The current for measurement is about 45 mA , while the current when shutdown is about 20 uA.)

Power Supply

Battery Mode: 6V, 4 x AAA batteries

Содержание LS208-B6

Страница 1: ...437 China TEL 86 760 88282982 www transtek cn User Manual Body Fat Analyzer LS208 B6 Please do read the user manual carefully and thoroughly so as to ensure the safe usage of this product and keep the...

Страница 2: ...up Start Measuring Daily Measurement Manage Your Health Data Transmission Troubleshooting Error Prompt When Measuring When Data Transmitting Specifications Maintenance Warranty FCC Regulations Append...

Страница 3: ...manual Don t expose the device to extreme temperatures direct sunlight moist or corrosive environment Do not step on the scale when your body or feet are wet especially after bathing or showering to...

Страница 4: ...3 User Manual Device Components LED Display Overview Overview LED Display Glass UNIT and activation Button Battery Compartment Sensor Bioelectrical Impedance Analysis Pound Kilogram Data pending to t...

Страница 5: ...are equipped with Bluetooth function in line with BLE Technical Specifications as well as BLP Protocol established by global organization Bluetooth SIG are capable to receive your personal health dat...

Страница 6: ...should be paired to a Bluetooth 4 0 end How to mitigate possible interference 1 The range between the Analyzer and the Bluetooth end should be reasonably close from 1 meter to 10 meters Please ensure...

Страница 7: ...There has data doesn t upload The notebook icon will be displayed Upload the data Warm up your hands and feet to resume blood circulation and then measure again Cold body that may results in bad blood...

Страница 8: ...5kg Working Environment Temperature 5 to 40 Storage Environment Temperature 20 to 60 Power Source 6V Four AAA size Batteries Turn on Method SENSE ON technology Auto OFF Accessories 1 Four AAA size ba...

Страница 9: ...ed environment In order to avoid the possiblity of exceeding the FCC radio frequency exposure limits human proximity to the antenna shall not be less than 20 cm 8 inches during normal operation FCC Re...

Страница 10: ...tromagnetic environment specified below The customer or the user of the device should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF em...

Страница 11: ...E EQUIPMENT and ME SYSTEMS that are not LIFE SUPPORTING Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test IEC 60601 TEST LEVEL Compliance level Electromagnetic environment...

Страница 12: ...on distance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz P V d 5 3 1 80 MHz to 800 MHz 800 MHz to 2 5 GHz 1 0 0 1 0 1 0 1 0 0 1 For transmitter...

Отзывы: