Safety Information

Safety Information

The warning signs and symbols are essential to ensure your correct and safe use of 

this product and protect you and others from injury. Please kindly find the meanings of the 

warning signs and symbols, which you may encounter in the label and user manual, as 

follows:

Safety and Usage Information

INDICATIONS FOR USE

The Transtek Body Fat Analyzer measures weight and uses bio-electrical impedance analysis 

(BIA) technology to estimate body fat, total body water percentage, bone mass, and muscle 

mass in generally healthy children 10-17 years old and healthy adults. 

It is intended for use in the domestic setting only. 

     Transtek’s Body Fat Analyzer LS208-B6 offers you a seamless way to manage your 

health. Please be aware that this device is designed for healthy population over 10 years old 

self-measuring and self-monitoring body compositions. Any information provided by this 

device is in no way meant to treat, cure or prevent any disease or illness from happening. 

If in doubt, contact your physician.

     This device is contraindicated for any female subject who may be suspected of, or is 

pregnant. Otherwise, the effects of this device on the fetus are unknown.

     This device is contraindicated for any person who is connected to a wearable or implantable 

electronic device or instrument such as a pacemaker or defibrillator.

     This device should not be used for anyone who is acutely or chronically ill because of 

suffering from a disease or taking medications that affect your water levels. The accuracy of 

readings for these patients has not been verified. Specific medical advice should be obtained 

from a physician.  

     LS208-B6 is equipped with data transmission function. It may emit electromagnetic 

energy so as to perform its intended function. Nearby portable and mobile RF communications

equipment can affect the performance of LS208-B6. And the device can interfere vicinity 

electrical equipment.

      Manufacturer will make available on request circuit diagrams, component parts list,etc.

     WARNING:No modifications of this equipment is allowed. This may result in increased 

EMISSIONS or decreased IMMUNITY of LS208-B6.

     Please use the device according to the user manual. Any misuse can cause electric shock,

burns, fire and other unexpected hazards.

    Please use and storage the device under the environment which was provided in the user 

manual. 

    Don’t expose the device to extreme temperatures, direct sunlight, moist or corrosive 

environment.

    Do not step on the scale when your body or feet are wet, especially after bathing or 

showering to prevent slipping.

CAUTION

Symbol for “THE OPERATION 

GUIDE MUST BE READ”

Symbol for “MANUFACTURER”

Symbol for “ENVIRONMENT 

PROTECTION – Waste electrical 

products should not be disposed of with 

household waste. Please recycle where 

facilities exist. Check with your local 

authority or retailer for recycling advice”

Symbol for “TYPE BF APPLIED 

PARTS” 

The Bluetooth Combination Mark

Symbol for “SERIAL NUMBER”

Symbol for “MANUFACTURE 

DATE”

Symbol for “DIRECT CURRENT”

Tips

To ensure the accuracy of measurement, please follow below instructions when 

you start measurement.

Place the scale on a flat, hard surface. Soft surface such as carpet will affect the 

performance of the scale.
Step onto the platform with bare feet. Stand still and keep full contact with the electrodes 

until the measurement is complete.
Start measurement at least two hours after Getting up or Dinning.
Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and 

dinning.
Always start measurement in the same time slot and on the same scale located on the 

same flat, hard surface.

For maximum accuracy and repeatability , it is recommended that you should use the 

device in the same time of the day and on the same location. 

Body fat percentage estimates will vary with the amount of water in the body, and can 

be affected by dehydration or over-hydration due to such factors as alcohol consumption, 

menstruation, illness, intense exercise, etc.

The condition of the skin on the bottom of your feet can affect the reading. The natural 

effects of aging or activity can make this skin hard. Take the reading with clean, slightly 

damp feet for best accuracy. If you are having a problem on operating this scale please 

contact customer service.

  To prevent you from injury, please pay attention to the following Notice.

A list of known devices or other sources that can potentially cause interference problems 

(example 1  Heat from a fireplace or radiant heater.  example 2  Moisture from a nebuliser 

or steam kettle). 

Small parts being inhaled or swallowed. 
Potential allergic reactions to accessible materials used in the ME EQUIPMENT. 
Contact injuries.  
Use accessories, detachable parts and materials not described in the instructions for use. 

The effects caused by pets, pests or children.

The effects of degraded sensors and electrodes, or loosened electrodes, that can degrade 

performance or cause other problems. 

Содержание LS208-B6

Страница 1: ...437 China TEL 86 760 88282982 www transtek cn User Manual Body Fat Analyzer LS208 B6 Please do read the user manual carefully and thoroughly so as to ensure the safe usage of this product and keep the...

Страница 2: ...up Start Measuring Daily Measurement Manage Your Health Data Transmission Troubleshooting Error Prompt When Measuring When Data Transmitting Specifications Maintenance Warranty FCC Regulations Append...

Страница 3: ...manual Don t expose the device to extreme temperatures direct sunlight moist or corrosive environment Do not step on the scale when your body or feet are wet especially after bathing or showering to...

Страница 4: ...3 User Manual Device Components LED Display Overview Overview LED Display Glass UNIT and activation Button Battery Compartment Sensor Bioelectrical Impedance Analysis Pound Kilogram Data pending to t...

Страница 5: ...are equipped with Bluetooth function in line with BLE Technical Specifications as well as BLP Protocol established by global organization Bluetooth SIG are capable to receive your personal health dat...

Страница 6: ...should be paired to a Bluetooth 4 0 end How to mitigate possible interference 1 The range between the Analyzer and the Bluetooth end should be reasonably close from 1 meter to 10 meters Please ensure...

Страница 7: ...There has data doesn t upload The notebook icon will be displayed Upload the data Warm up your hands and feet to resume blood circulation and then measure again Cold body that may results in bad blood...

Страница 8: ...5kg Working Environment Temperature 5 to 40 Storage Environment Temperature 20 to 60 Power Source 6V Four AAA size Batteries Turn on Method SENSE ON technology Auto OFF Accessories 1 Four AAA size ba...

Страница 9: ...ed environment In order to avoid the possiblity of exceeding the FCC radio frequency exposure limits human proximity to the antenna shall not be less than 20 cm 8 inches during normal operation FCC Re...

Страница 10: ...tromagnetic environment specified below The customer or the user of the device should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF em...

Страница 11: ...E EQUIPMENT and ME SYSTEMS that are not LIFE SUPPORTING Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test IEC 60601 TEST LEVEL Compliance level Electromagnetic environment...

Страница 12: ...on distance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz P V d 5 3 1 80 MHz to 800 MHz 800 MHz to 2 5 GHz 1 0 0 1 0 1 0 1 0 0 1 For transmitter...

Отзывы: