1800 816 277
www.tti.com.au
10
Product HandBook
VersatileBoom™
Figure 6 – Off-centre end jet nozzle installation
NOTE: Ensure the brass nozzle tip is orientated such that the arrow shape is
pointing inwards.
7. Screw the nozzle cap assembly onto the off-centre end jet port body. The nozzle tip must be orientated
such that the open end of the triangle shape orifice is facing outwards, that is, the arrow shape is pointing
inwards.
8. Tighten the nozzle cap firmly.
9. Repeat steps 6 to 8 for the second end jet nozzle.
10. At first use, fill the spray unit with water for calibration of the VersatileBoom, refer to the calibration
procedure below.
VersatileBoom Calibration
Accurate calibration is an essential element of any spraying function as it ensures that the chemical is applied
at the rate specified on the product label. Application in excess of the recommended rate may be dangerous,
can damage crops and is uneconomical.
Calibration must be carried out:
• When spraying for the first time with new spray equipment
• At the beginning of each season
• After changes of nozzle tips, spraying pressure or vehicle speed
• After every 100 hectares of spraying