TransTank AquaDelivery Скачать руководство пользователя страница 18

1800  816  277

www.tti.com.au

18

Product HandBook

AquaDelivery

TroubleShooting

If a fault develops with the AquaDelivery, the following trouble shooting table provides guidance to identify 
and rectify the problem.

Problem

Possible Cause

Remedy

Pump will not feed water Ball valve closed on outlet

Open ball valve

Engine will not crank 
(petrol or optional diesel 
engine) 

Flat battery

Check battery state-of-charge

Melted fusible link/circuit breaker

Replace fusible link/breaker

Loose Connections

Clean and tighten connections

Faulty Ignition Switch

Check switch operation, replace as needed

Faulty magnetic, relay, neutral start or clutch 

switches

Check and replace as needed

Mechanical problem in engine

Check Engine

Problem in theft deterrent system

Check service manual for system tests

Engine cranks too 
slowly to start

Weak Battery

Check battery and charge as needed

Loose or corroded connections

Clean and tighten connections

Faulty starter motor

Test Starter

Mechanical problems with engine or starter

Check engine and starter, replace worn out parts

Starter keeps running

Damaged pinion or ring gear

Check gears for wear or damage

Faulty plunger in magnetic switch

Test starter pull-in and hold-in coils

Faulty ignition switch or control circuit

Check switch and circuit components

Binding ignition key

Check key for damage

Starter spins, but engine 
will not crank

Faulty over-running clutch

Check over-running clutch for proper operation

Damaged or worn pinion gear or ring gear

Check gears for damage and wear; replace as 

needed

Starter does not 
engage/disengage 
properly 

Faulty magnetic switch

Bench test starter

Damaged or worn pinion gear or ring gear

Check gears for damage and wear; replace as 

needed

Содержание AquaDelivery

Страница 1: ...Operator s HandBook AquaDelivery w w w t t i c o m a u Manufacturer of The Safest Tanks in Motion ...

Страница 2: ...ons 9 Before First Use 9 Pump Operation Petrol Engine 10 Pump Operation Diesel Engine Option 11 Filling the Tank 11 AquaDelivery Operation 12 AquaDelivery Loading Procedure 13 Risk Assessment 14 Maintenance 15 Periodic Checks 15 Maintenance 15 Maintenance Schedule 16 Trouble Shooting 18 Warranty 19 Warranty Policy 19 What this Warranty Does Not Cover 19 How to Obtain Service Under this Warranty 19...

Страница 3: ...where necessary All TTi AquaDelivery tanks are rotationally moulded from quality polyethylene purpose designed and manufactured to high standards The AquaDelivery is a steel frame mounted water transport system designed for potable water delivery With a heavy duty galvanised steel frame with forklift pockets the AquaDelivery is easy to load onto any tipper flat tray or trailer The AquaDelivery uni...

Страница 4: ...rity A NOTE highlights or clarifies an essential systems description operating or maintenance procedure condition or statement A WARNING highlights an essential operating or maintenance procedure practice condition or statement which if not strictly observed could result in injury or death of personnel or long term health hazards A CAUTION highlights an essential operating or maintenance procedure...

Страница 5: ... relevant safety instructions Do not exceed the carrying and braking capacity as specified by the vehicle manufacturer As a guide one litre of water weights one kilogram kg therefore a full 5 000 litre AquaDelivery will weigh in excess of 5 500kg 9 The unit must be securely restrained when being transported on a vehicle Ensure all bolts and fasteners are tightened and secure before operation 10 Be...

Страница 6: ... Standard Equipment Honda GX200 electric start petrol engine with 1 000L min 3 Aussie QP303 pump Pressure regulator Hydrant Fill System with tilt lid 2 x 10m 3 layflat hose and Camlock fittings Potable Water Approved to AS4020 Tank bottom fill kit via integral pump Lockable aluminium hose stowage box Level sight tube Options Yanmar diesel engine upgrade LiquidLocker Baffle Safety System Loading Le...

Страница 7: ...small variance in the overall dimensions of the tank therefore calibration markings should be used as a guide only The tank has a tilt lid top opening funnel for hydrant filling The AquaDelivery is available in the following capacities 5 000 litres 6 000 litres 7 000 litres 8 000 litres 10 000 litres 12 000 litres 13 000 litres standard and low profile options 15 000 litres 17 000 litres LiquidLoc...

Страница 8: ...ry is installed behind the pump to provide power to start the petrol or optional diesel powered pump Layflat Hose EachAquaDeliveryissuppliedwithtwo10mlengthsoflayflathosewithcamlockfittings fordirectconnection to the pump and hydrant The certified Potable Water hose is stowed in a lockable aluminium box mounted on the steel frame adjacent to the pump Hydrant Fill Kit A hydrant fill kit is standard...

Страница 9: ...long with the Tank Quality Check Form and pump unit s manual in the provided leather pouch in a safe and easily accessible place for future reference NOTE The operator must fully understand all aspects of this handbook Do not operate the AquaDelivery if you are unfamiliar with its operation until you have read this handbook Read and thoroughly understand this handbook paying particular attention t...

Страница 10: ...throttle lever to idle for cold starting If restarting a warm engine the throttle can be left at normal engine operating speed NOTE Ensure the ignition key is switched ON The engine will crank in the OFF position but will not start unless switched to ON SInsert the key and switch the engine to the START position When the engine starts release the key which will return to the ON position Back off t...

Страница 11: ...el Insert the key and switch the engine to the START position When the engine starts release the key which will return to the ON position Once warmed up adjust the engine speed to normal operating revs using the throttle lever When the engine needs to be stopped turn the ignition OFF If the AquaDelivery is not going to be used within the next few hours shut the system down by turning the fuel tap ...

Страница 12: ...the supply hydrant s valve The tilt lid will fall flat to close off the tank s opening to prevent debris entering Disconnect the hydrant supply hose Clean and dry the hose before stowing it in the aluminium storage box mounted adjacent to the pump unit Figure 3 Hydrant Filling Operation AquaDelivery Operation The AquaDelivery Bulk Water Delivery Unit is operated as follows Install the unit onto th...

Страница 13: ...a tipper tray or mount on a flat tray or trailer and when not required can be easily removed The AquaDelivery unit is loaded as follows WARNING The AquaDelivery is heavy and must be loaded or unloaded correctly Ensure this procedure is followed exactly to avoid injury or death to personnel or damage to the unit CAUTION The AquaDelivery unit must never be unloaded with water in the tank Ensure the ...

Страница 14: ... lift on your own if 20kg bend knees keep back straight Keep fingers clear Keep unit at least 8m away from overhead powerlines Fire extinguisher nearby Follow warning stickers on tanks Wear PPE for petrol diesel fumes mask gloves Check weather conditions Manual handling slips trips or falls Low Follow safe manual handling techniques don t lift on your own if 20kg bend knees keep back straight Use ...

Страница 15: ...ozzle Rewind the hose onto the reel ensuring it retracts all the way For the petrol or optional diesel engine driven pump check the engine s oil level weekly Top up as required Check for any signs of fuel or oil leaks If detected investigate and rectify immediately Check the condition of the optional diesel or petrol pump engine s 12 volt battery replace it or charge it as necessary If the AquaDel...

Страница 16: ... to each use of the AquaDelivery unit No Task Notes 1 Inspect the AquaDelivery for any signs of damage or wear Clean repair or replace 2 Check fuel Top up as required 3 Inspect engine s air filter and housing for dust Clean replace as necessary Weekly Tasks The following tasks are to be undertaken each week or 10 operating hours whichever occurs first No Task Date Signed 1 All Daily tasks 2 Remove...

Страница 17: ...y Weekly Monthly and 3 Monthly tasks 2 Change engine oil and filter if fitted 3 Inspect spark plug petrol engine only Twelve Monthly tasks The following tasks are to be undertaken every twelve months or 200 operating hours whichever occurs first No Task Date Signed 1 All Daily Weekly Monthly 3 Monthly 6 Monthly tasks 2 Check the battery condition 3 Replace the engine s air filter 4 Drain and flush...

Страница 18: ...mintheftdeterrentsystem Checkservicemanualforsystemtests Enginecrankstoo slowlytostart WeakBattery Checkbatteryandchargeasneeded Looseorcorrodedconnections Cleanandtightenconnections Faultystartermotor TestStarter Mechanicalproblemswithengineorstarter Checkengineandstarter replacewornoutparts Starterkeepsrunning Damagedpinionorringgear Checkgearsforwearordamage Faultyplungerinmagneticswitch Testst...

Страница 19: ... making service calls clean up time and transport charges 3 The use of non genuine parts on equipment supplied by TTi This will automatically negate any warranty How to Obtain Service Under this Warranty Warranty service can be arranged by contacting your dealer or by contacting TTi directly on 1800 816 277 Proof of warranty registration and date of purchase may be required to verify warranty cove...

Страница 20: ...ti com au 1800 816 277 sales tti com au PO Box 137 Nathalia VIC 3638 Murray Valley Hwy Nathalia VIC 3638 Proudly Built By Signature Date Signature Date Quality Checked By Scan to view our PDF Handbook online ...

Отзывы: